摘要
A polyion complex membrane containing physically entrapped microperoxidase and ferrocene was prepared on a glassy carbon electrode. A reductive current response for H2O2 was obtained under the application of 0.0 V versus Ag \ AgCl. The current response was proportional to the H2O2 concentration up to 20 mu M, and the lower detection limit was 0.5 mu M (S/N = 5). The interference current from L-ascorbate was ca. 45% of the current for the same concentration of H2O2. The electrode could be used for 10 days. The electrode was applied as the transducer of an oxidase-based sensor such as a glucose oxidase-based one: the glucose-sensing electrode prepared showed high sensitivity (lower detection limit, 5 mu M). (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:117 / 120
页数:4
相关论文
共 14 条
[2]   AMPEROMETRIC ENZYMATIC DETERMINATION OF TOTAL CHOLESTEROL IN HUMAN-SERUM WITH TUBULAR CARBON ELECTRODES [J].
HAHN, Y ;
OLSON, CL .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :444-449
[3]   CHEMICAL SENSORS [J].
JANATA, J ;
JOSOWICZ, M ;
DEVANEY, DM .
ANALYTICAL CHEMISTRY, 1994, 66 (12) :R207-R228
[4]   THE DEVELOPMENT OF BIENZYME GLUCOSE ELECTRODES [J].
KULYS, JJ ;
PESLIAKIENE, MV ;
SAMALIUS, AS .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1981, 8 (01) :81-88
[5]   SIMULTANEOUS DETERMINATION OF GLUCOSE, FRUCTOSE, AND SUCROSE IN MIXTURES BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYME REACTORS [J].
MATSUMOTO, K ;
KAMIKADO, H ;
MATSUBARA, H ;
OSAJIMA, Y .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :147-151
[6]   ASCORBATE ELECTRODE FOR DETERMINATION OF L-ASCORBIC-ACID IN FOOD [J].
MATSUMOTO, K ;
YAMADA, K ;
OSAJIMA, Y .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :1974-1979
[7]   Flow injection analysis of L-lactic acid using an enzyme-polyion complex-coated electrode as the detector [J].
Mizutani, F ;
Yabuki, S ;
Hirata, Y .
TALANTA, 1996, 43 (10) :1815-1820
[8]   Amperometric alcohol-sensing electrode based on a polyion complex membrane containing alcohol oxidase [J].
Mizutani, F ;
Yabuki, S ;
Iijima, S .
ANALYTICAL SCIENCES, 1997, 13 (01) :83-87
[9]   SIMULTANEOUS DETERMINATION OF GLUCOSE AND SUCROSE BY A GLUCOSE-SENSING ENZYME ELECTRODE COMBINED WITH AN INVERTASE-ATTACHED CELL [J].
MIZUTANI, F ;
ASAI, M .
ANALYTICA CHIMICA ACTA, 1990, 236 (02) :245-250
[10]   Amperometric biosensors using poly-L-lysine/poly(styrenesulfonate) membranes with immobilized enzymes [J].
Mizutani, F ;
Yabuki, S ;
Hirata, Y .
DENKI KAGAKU, 1995, 63 (12) :1100-1105