Synchronous measurements of blood pressure and red blood cell velocity in capillaries of human skin

被引:18
作者
Hahn, M [1 ]
Klyscz, T [1 ]
Junger, M [1 ]
机构
[1] UNIV TUBINGEN HOSP,DEPT DERMATOL,MICROVASC LAB,D-72076 TUBINGEN,GERMANY
关键词
hemodynamics; skin blood flow; capillary blood pressure; capillary red blood; cell velocity;
D O I
10.1111/1523-1747.ep12348955
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
We have devised a system for analyzing the temporal coherence of capillary pressure (CP) and capillary red blood cell velocity (CBV) variations in humans, The system is designed to measure human blood pressure in skin capillaries by direct cannulation while simultaneously measuring red blood cell velocity in the same capillary by video microscopy. The servo-nulling pressure measurement system allows the dynamic recording of capillary pressure with a flat frequency response of about 12 Hz. Computerized data acquisition is synchronized with the frame code of a U-matic video recorder, which records the capillaroscopic picture for later computerized off-line analysis of capillary red blood cell velocity, Measurements of simultaneously recorded CP and CBV in healthy volunteers show synchronized pulsation. Minimal pulsatile variations in CP values result in marked variations of CBV, In addition, minor fluctuations (3-4 cycles per minute) in CP are accompanied by marked changes in CBV. This system may help provide information about microvascular pathophysiology in skin diseases before and after treatment.
引用
收藏
页码:1256 / 1259
页数:4
相关论文
共 19 条
  • [1] RED BLOOD-CELL VELOCITY IN NAILFOLD CAPILLARIES OF MAN MEASURED BY A TELEVISION MICROSCOPY TECHNIQUE
    BOLLINGER, A
    BUTTI, P
    BARRAS, JP
    TRACHSLER, H
    SIEGENTHALER, W
    [J]. MICROVASCULAR RESEARCH, 1974, 7 (01) : 61 - 72
  • [2] Capillary and venous pressure in man
    Carrier, EB
    Rehberg, PB
    [J]. SKANDINAVISCHES ARCHIV FUR PHYSIOLOGIE, 1923, 44 (1/2): : 20 - 31
  • [3] EICHNA IW, 1939, J CLIN INVEST, V18, P695
  • [4] Capillary blood pressure in man - Direct measurements in the digits of normal and hypertensive subjects during vasoconstriction and vasodilatation variously induced
    Eichna, LW
    Bordley, J
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1942, 21 (06) : 711 - 729
  • [5] FAHR GE, 1940, ANN INTERN MED, V15, P798
  • [6] GAEHTGENS P, 1987, BIORHEOLOGY, V24, P367
  • [7] CAPILLARY BLOOD-CELL VELOCITY IN FINGER NAILFOLD - CHARACTERISTICS AND REPRODUCIBILITY OF THE LOCAL COLD RESPONSE
    GASSER, P
    [J]. MICROVASCULAR RESEARCH, 1990, 40 (01) : 29 - 35
  • [8] PRODUCTION OF MICROPERFUSION PIPETTES SUITABLE FOR USE WITH COLORLESS SOLUTIONS
    HABERLE, DA
    DAVIS, JM
    MAYER, G
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1978, 376 (02): : 191 - 192
  • [9] LANDIS EM, 1930, HEART, V15, P798
  • [10] EFFECTS OF POSITION AND SKIN TEMPERATURE ON CAPILLARY PRESSURES IN FINGERS AND TOES
    LEVICK, JR
    MICHEL, CC
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1978, 274 (JAN): : 97 - +