Levels of inflammatory markers in the blood processed by autotransfusion devices during cardiac surgery associated with cardiopulmonary bypass circuit

被引:65
作者
Amand, T
Pincemail, J
Blaffart, F
Larbuisson, R
Limet, R
Defraigne, JO
机构
[1] Univ Liege, CHU, Dept Cardiovasc Surg, B-4000 Liege, Belgium
[2] CHR, Liege, Belgium
[3] Ctr Expt Surg, CREDEC, Liege, Belgium
[4] Univ Liege, CHU, Dept Anaesthesiol, Liege, Belgium
来源
PERFUSION-UK | 2002年 / 17卷 / 02期
关键词
D O I
10.1191/0267659102pf544oa
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intraoperative blood salvage devices allowing a reinfusion of red blood cells (RBCs) after processing of shed blood and stagnant blood in the mediastinal cavity are more and more used to reduce homologous blood requirements in cardiac surgery with cardiopulmonary bypass (CPB). As the proinflammatory activity of the shed blood also contributes to morbidity during CPB, we conducted a prospective study in order to examine the quality of autologous blood before and after processing with five different devices [BRAT2, Sequestra, Compact Advanced, Cell Saver 5 (CS5), Continuous Autologous Transfusion System (CATS)]. All systems resulted in an excellent haemoconcentration, ranging from 53.7% (Compact) to 68.9% (CATS). The concentrations and elimination rates of several inflammatory markers [IL-1beta, IL-2, IL-8, TNFalpha, myeloperoxidase (MPO), elastase] were examined. Except for the Sequestra, an important increase in concentration of IL-1beta (between 30% and 220%) has been observed after processing with each device. In contrast, the attenuation rate of IL-6 and TNFalpha (95%) was optimal for all investigated blood salvages systems. Regarding IL-8, only the CATS and CS5 systems were able to attenuate this biological parameter with an excellent efficacy. The rate of attenuation in MPO and elastase, as markers of leukocyte activation, was higher than 80% for all devices. In conclusion, the different RBC washing systems tested in this study resulted in a significant attenuation of the inflammatory response. Increased levels of IL-1beta after processing remained, however, unclear. According to the type of protocol, based on inlet haematocrit, fill and wash speeds, and wash volumes, small variations in reducing the inflammatory response have been observed from one device to another.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 31 条
[1]   Mechanisms of the systemic inflammatory response [J].
Asimakopoulos, G .
PERFUSION-UK, 1999, 14 (04) :269-277
[2]  
BERTY A, 1986, Perfusion (London), V1, P179, DOI 10.1177/026765918600100305
[3]  
BULL BS, 1990, BLOOD CELLS, V16, P5
[4]  
Casey LC, 1993, ANN THORAC SURG, V56, P92
[5]  
Courtney James M., 1994, Perfusion, V9, P3, DOI 10.1177/026765919400900102
[6]   Cytokine release and neutrophil activation are not prevented by heparin-coated circuits and aprotinin administration [J].
Defraigne, JO ;
Pincemail, J ;
Larbuisson, R ;
Blaffart, F ;
Limet, R .
ANNALS OF THORACIC SURGERY, 2000, 69 (04) :1084-1091
[7]   SMA circuits reduce platelet consumption and platelet factor release during cardiac surgery [J].
Defraigne, JO ;
Pincemail, J ;
Dekoster, G ;
Larbuisson, R ;
Dujardin, M ;
Blaffart, F ;
David, JL ;
Limet, R .
ANNALS OF THORACIC SURGERY, 2000, 70 (06) :2075-2081
[8]   RETRANSFUSION OF SUCTIONED BLOOD DURING CARDIOPULMONARY BYPASS IMPAIRS HEMOSTASIS [J].
DEHAAN, J ;
BOONSTRA, PW ;
MONNINK, SHJ ;
EBELS, T ;
VANOEVEREN, W .
ANNALS OF THORACIC SURGERY, 1995, 59 (04) :901-907
[9]  
DEWITZ TS, 1979, BLOOD CELLS, V5, P499
[10]  
DZIK WH, 1993, ANN THORAC SURG, V56, P95