Comparison of the 2007 and 2011 Appropriate Use Criteria for Transthoracic Echocardiography in Various Clinical Settings

被引:49
作者
Bhatia, R. Sacha [1 ]
Carne, Dana M. [1 ]
Picard, Michael H. [1 ]
Weiner, Rory B. [1 ]
机构
[1] Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
关键词
Appropriate use criteria; Transthoracic echocardiography; CARDIOLOGY FOUNDATION/AMERICAN SOCIETY; OF-CARDIOLOGY; AMERICAN-SOCIETY; HEART-FAILURE; RECOMMENDATIONS; GUIDELINES; DIAGNOSIS; MEDICARE;
D O I
10.1016/j.echo.2012.07.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The 2007 Appropriate Use Criteria (AUC) for echocardiography was revised in 2011 to cover a wider range of scenarios of use. Previous studies of the 2007 AUC found a relatively large number of unclassified transthoracic echocardiograms (TTEs). Methods: We conducted a retrospective chart review comparing TTE usage in three clinical environments: academic inpatient, academic outpatient, and community outpatient. We assessed the TTE ordering behavior using both the 2007 and 2011 AUC. Results: We reviewed 150 consecutive TTEs performed in 2011 in each of the three practice settings (total 450). Using the 2007 AUC, 347 TTEs (77%) were classifiable, and, using the 2011 AUC, 441 TTEs (98%) were classifiable (P < .001). Of the classified studies, the percentage of appropriate TTEs using the 2007 AUC was 83% and using the 2011 AUC was 71% (P < .001). Using the 2007 and 2011 AUC, the percentage of inappropriate TTEs was 17% and 22% (P = .14), and the percentage of uncertain TTEs was 0% and 7% (P < .001), respectively. The rate of inappropriate studies was greatest in the outpatient academic medical center (30%), followed by the outpatient community health center (21%) and the inpatient academic medical center (14%; P = .004). Conclusions: The 2011 AUC classified a significantly greater proportion of TTEs than the 2007 AUC across a variety of practice settings. The rate of appropriate TTEs was lower using the 2011 AUC, and the appropriateness ratings varied by clinical setting. These findings suggest that the expanded AUC offer an opportunity for improvement in TTE usage. (J Am Soc Echocardiogr 2012;25:1162-9.)
引用
收藏
页码:1162 / 1169
页数:8
相关论文
共 25 条
[1]   Application of the Appropriateness Criteria for Echocardiography in an Academic Medical Center [J].
Aggarwal, Niti R. ;
Wuthiwaropas, Punsak ;
Karon, Barry L. ;
Miller, Fletcher A. ;
Pellikka, Patricia A. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (03) :267-274
[2]   Proliferation of cardiac technology in Canada - A challenge to the sustainability of Medicare [J].
Alter, DA ;
Stukel, TA ;
Newman, A .
CIRCULATION, 2006, 113 (03) :380-387
[3]   Application of 2011 American College of Cardiology Foundation/American Society of Echocardiography Appropriateness Use Criteria in Hospitalized Patients Referred for Transthoracic Echocardiography in a Community Setting [J].
Ballo, Piercarlo ;
Bandini, Fabrizio ;
Capecchi, Irene ;
Chiodi, Leandro ;
Ferro, Giuseppe ;
Fortini, Alberto ;
Giuliani, Gabriele ;
Landini, Giancarlo ;
Laureano, Raffaele ;
Milli, Massimo ;
Nenci, Gabriele ;
Pizzarelli, Francesco ;
Santoro, Giovanni Maria ;
Vannelli, Pasquale ;
Cappelletti, Carlo ;
Zuppiroli, Alfredo .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (06) :589-598
[4]   Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) :1-23
[5]   Cardiac-resynchronization therapy in heart failure with narrow QRS complexes [J].
Beshai, John F. ;
Grimm, Richard A. ;
Nagueh, Sherif F. ;
Baker, James H., II ;
Beau, Scott L. ;
Greenberg, Steven M. ;
Pires, Luis A. ;
Tchou, Patrick J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (24) :2461-2471
[6]   Use of a Web-Based Application of the American College of Cardiology Foundation/American Society of Echocardiography Appropriateness Use Criteria for Transthoracic Echocardiography: A Pilot Study [J].
Bhave, Nicole M. ;
Mansour, Ibrahim N. ;
Veronesi, Federico ;
Razi, Rabia R. ;
Lang, Roberto M. ;
Ward, R. Parker .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (03) :271-276
[7]   Results of the predictors of response to CRT (PROSPECT) trial [J].
Chung, Eugene S. ;
Leon, Angel R. ;
Tavazzi, Luigi ;
Sun, Jing-Ping ;
Nihoyannopoulos, Petros ;
Merlino, John ;
Abraham, William T. ;
Ghio, Stefano ;
Leclercq, Christophe ;
Bax, Jeroen J. ;
Yu, Cheuk-Man ;
Gorcsan, John, III ;
Sutton, Martin St John ;
De Sutter, Johan ;
Murillo, Jaime .
CIRCULATION, 2008, 117 (20) :2608-2616
[8]  
Douglas Pamela S, 2007, J Am Coll Cardiol, V50, P187, DOI 10.1016/j.jacc.2007.05.003
[9]   ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography [J].
Douglas, Pamela S. ;
Garcia, Mario J. ;
Haines, David E. ;
Lai, Wyman W. ;
Manning, Warren J. ;
Patel, Ayan R. ;
Picard, Michael H. ;
Polk, Donna M. ;
Ragosta, Michael ;
Ward, R. Parker ;
Weiner, Rory B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (09) :1126-1166
[10]   Guidelines for the diagnosis and treatment of pulmonary hypertension [J].
Galie, Nazzareno ;
Hoeper, Marius M. ;
Humbert, Marc ;
Torbicki, Adam ;
Vachiery, Jean-Luc ;
Albert Barbera, Joan ;
Beghetti, Maurice ;
Corris, Paul ;
Gaine, Sean ;
Gibbs, J. Simon ;
Angel Gomez-Sanchez, Miguel ;
Jondeau, Guillaume ;
Klepetko, Walter ;
Opitz, Christian ;
Peacock, Andrew ;
Rubin, Lewis ;
Zellweger, Michael ;
Simonneau, Gerald .
EUROPEAN HEART JOURNAL, 2009, 30 (20) :2493-2537