Nitrous oxide does not alter bispectral index:: study with nitrous oxide as sole agent and as an adjunct to i.v. anaesthesia

被引:125
作者
Barr, G
Jakobsson, JG
Öwall, A
Anderson, RE [1 ]
机构
[1] Karolinska Hosp, Dept Cardiothorac Anaesthet & Intens Care, S-17176 Stockholm, Sweden
[2] Sabbatsbergs Hosp, Dept Anaesthesiol, S-11324 Stockholm, Sweden
关键词
anaesthetics gases; nitrous oxide; monitoring; bispectral index; anaesthesia; depth; memory; surgery; cardiovascular;
D O I
10.1093/bja/82.6.827
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have studied the effect of nitrous oxide on bispectral index (BIS), calculated from a bipolar encephalogram. Inhalation of 70% nitrous oxide resulted in loss of consciousness in all healthy volunteers (n = 10) but no change in BIS. Brief inhalation up to 1.2% sevoflurane also resulted in loss of consciousness in volunteers (n = 5), but with sevoflurane, BIS decreased. BIS and the haemodynamic effects of adding nitrous oxide were also measured during coronary artery bypass surgery in patients (n = 10) receiving midazolam and fentanyl infusions. Measurements were made after 0%, 33%, 66% and 0% nitrous oxide, just before skin incision and after sternotomy. Nitrous oxide caused no change in BIS. BIS may indicate a sufficient hypnotic depth to prevent awareness during surgery, but our study demonstrated that pharmacological unconsciousness-hypnosis can also be reached by mechanisms to which BIS is not sensitive. Thus BIS is a sufficient but not a necessary criterion for adequate depth of anaesthesia or prevention of awareness.
引用
收藏
页码:827 / 830
页数:4
相关论文
共 17 条
[1]   Opiate receptors in the periaqueductal gray mediate analgesic effect of nitrous oxide in rats [J].
Fang, F ;
Guo, TZ ;
Davies, MF ;
Maze, M .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1997, 336 (2-3) :137-141
[2]  
GHOURI AF, 1991, ANESTH ANALG, V72, P377
[3]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[4]   Electroencephalographic derivatives as a tool for predicting the depth of sedation and anesthesia induced by sevoflurane [J].
Katoh, T ;
Suzuki, A ;
Ikeda, K .
ANESTHESIOLOGY, 1998, 88 (03) :642-650
[5]   Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis [J].
Kearse, LA ;
Rosow, C ;
Zaslavsky, A ;
Connors, P ;
Dershwitz, M ;
Denman, W .
ANESTHESIOLOGY, 1998, 88 (01) :25-34
[6]   Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol-induced sedation [J].
Liu, J ;
Singh, H ;
White, PF .
ANESTHESIA AND ANALGESIA, 1997, 84 (01) :185-189
[7]  
MASAHIRO K, 1989, SAAD DIGEST, V7, P206
[8]   EARLY CORTICAL AUDITORY EVOKED-RESPONSE IN ANESTHESIA - COMPARISON OF THE EFFECTS OF NITROUS-OXIDE AND ISOFLURANE [J].
NEWTON, DEF ;
THORNTON, C ;
CREAGHBARRY, P ;
DORE, CJ .
BRITISH JOURNAL OF ANAESTHESIA, 1989, 62 (01) :61-65
[9]   Nitrous oxide has different effects on the EEG and somatosensory evoked potentials during isoflurane anaesthesia in patients [J].
Porkkala, T ;
Jantti, V ;
Kaukinen, S ;
Hakkinen, V .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1997, 41 (04) :497-501
[10]   Bispectral EEG index during nitrous oxide administration [J].
Rampil, IJ ;
Kim, JS ;
Lenhardt, R ;
Negishi, C ;
Sessler, DI .
ANESTHESIOLOGY, 1998, 89 (03) :671-677