Quantitative visualization of flow through a centrifugal blood pump: Effect of washout holes

被引:12
作者
Nishida, M
Yamane, T
Orita, T
Asztalos, B
Clarke, H
机构
[1] TECH UNIV BUDAPEST, BUDAPEST, HUNGARY
[2] UNIV CAMBRIDGE, CAMBRIDGE, ENGLAND
关键词
flow visualization; centrifugal pump; similar flow; washout hole; gap flow; recirculatory flow;
D O I
10.1111/j.1525-1594.1997.tb03730.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To clarify the effect of washout holes on the flow in a centrifugal blood pump to prevent blood stagnation, a quantitative flow visualization technique was applied to compare flows in models with and without washout holes. A scaled-up model of a prototype pump and a high speed video camera were used for the flow visualization, and images were processed by particle tracking velocimetry. Particular attention was paid to the flow through the gaps behind and in front of the impeller. The results showed that in the gap behind the impeller, washout holes caused not only an inward flow, but also an increase in the tangential velocities. In the gap in front of the impeller, washout holes caused an outward now and a decrease in the tangential velocities. Head now characteristics were little affected by the washout holes in this initial design for which the now through the washout holes was set to be approximately 10% of the flow in the external circuit. These results suggest that the flow through washout holes is significant in the prevention of blood stagnation in 2 ways. First, the inward radial velocity behind the impeller and outward velocity in front of the impeller result in fluid exchange, and second, a tangential velocity increase reduces fluid stagnation behind the impeller.
引用
收藏
页码:720 / 729
页数:10
相关论文
共 9 条
[1]  
ARAKI K, 1993, ARTIF ORGANS, V17, P307
[2]   LDA MEASUREMENTS OF MEAN VELOCITY AND REYNOLDS STRESS-FIELDS WITHIN AN ARTIFICIAL-HEART VENTRICLE [J].
BALDWIN, JT ;
DEUTSCH, S ;
GESELOWITZ, DB ;
TARBELL, JM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (02) :190-200
[3]  
Daily J. W., 1960, J. Basic Eng., V82, P217, DOI [10.1115/1.3662532, DOI 10.1115/1.3662532]
[4]  
Ikeda T, 1996, ARTIF ORGANS, V20, P132
[5]  
JIKUYA T, 1992, ARTIF ORGANS, V16, P599
[6]  
KOBAYASHI T, 1991, ASME FED, V128, P9
[7]  
KUROKAWA J, 1990, P 3 JAP CHIN JOINT C, V1, P101
[8]  
Schima H, 1992, ASAIO J, V38, pM220, DOI 10.1097/00002480-199207000-00024
[9]   DESIGN OF A CENTRIFUGAL BLOOD PUMP WITH MAGNETIC SUSPENSION [J].
YAMANE, T ;
IKEDA, T ;
ORITA, T ;
TSUTSUI, T ;
JIKUYA, T .
ARTIFICIAL ORGANS, 1995, 19 (07) :625-630