Developments in particle tracking using the Birmingham Positron Camera

被引:49
作者
Parker, DJ [1 ]
Allen, DA [1 ]
Benton, DM [1 ]
Fowles, P [1 ]
McNeil, PA [1 ]
Tan, M [1 ]
Beynon, TD [1 ]
机构
[1] UNIV BIRMINGHAM,SCH CHEM,BIRMINGHAM B15 2TT,W MIDLANDS,ENGLAND
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/S0168-9002(97)00301-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The RAL/Birmingham Positron Camera consists of a pair of MWPCs for detecting the pairs of back-to-back 511 keV photons arising from positron-electron annihilation. It was constructed in 1984 for the purpose of applying PET to engineering situations, and has been widely used for the non-invasive imaging of flow, including extensive studies on geological samples. The technique of Positron Emission Particle Tracking (PEPT), whereby a single positron-emitting tracer particle can be tracked at high speed, was developed at Birmingham and has proved a very powerful tool for studying the behaviour of granular materials in systems such as mixers and fluidised beds. In order to extend its effective field of view, the camera has recently been mounted on a motorised translation stage under computer control so that the motion of a tracer particle can be followed over a length of up to 1.5 m. A preliminary investigation into the feasibility of enhancing the PEPT technique using the singles count rates in the two detectors has also been undertaken.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 8 条
[1]  
BENTON DM, IN PRESS
[2]   A POSITRON CAMERA FOR INDUSTRIAL APPLICATION [J].
HAWKESWORTH, MR ;
ODWYER, MA ;
WALKER, J ;
FOWLES, P ;
HERITAGE, J ;
STEWART, PAE ;
WITCOMB, RC ;
BATEMAN, JE ;
CONNOLLY, JF ;
STEPHENSON, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 253 (01) :145-157
[3]  
LARACHI F, 1995, CHEM ENG RES DES, V73, P263
[4]  
LAURENT B, INP RESS
[5]   THE PERFORMANCE OF A MULTIWIRE PROPORTIONAL CHAMBER POSITRON CAMERA FOR CLINICAL USE [J].
MARSDEN, PK ;
OTT, RJ ;
BATEMAN, JE ;
CHERRY, SR ;
FLOWER, MA ;
WEBB, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (08) :1043-1062
[6]   RADIOACTIVE PARTICLE TRACKING TECHNIQUE FOR INVESTIGATION OF PHASE RECIRCULATION AND TURBULENCE IN MULTIPHASE SYSTEMS [J].
MOSLEMIAN, D ;
DEVANATHAN, N ;
DUDUKOVIC, MP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) :4361-4372
[7]   POSITRON EMISSION PARTICLE TRACKING - A TECHNIQUE FOR STUDYING FLOW WITHIN ENGINEERING EQUIPMENT [J].
PARKER, DJ ;
BROADBENT, CJ ;
FOWLES, P ;
HAWKESWORTH, MR ;
MCNEIL, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (03) :592-607
[8]   INDUSTRIAL POSITRON-BASED IMAGING - PRINCIPLES AND APPLICATIONS [J].
PARKER, DJ ;
HAWKESWORTH, MR ;
BROADBENT, CJ ;
FOWLES, P ;
FRYER, TD ;
MCNEIL, PA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3) :583-592