Design and implementation of an instrumented ulnar head prosthesis to measure loads in vitro

被引:15
作者
Gordon, Karen D.
Kedgley, Angela E.
Ferreira, Louis M.
King, Graham J. W.
Johnson, James A.
机构
[1] St Josephs Hlth Care London, Hand & Upper Limb Ctr, Bioengn Res Lab, London, ON N6A 4L6, Canada
[2] Univ Guelph, Sch Engn, Guelph, ON N1G 2W1, Canada
[3] Univ Western Ontario, Dept Biomed Engn, London, ON N6A 3K7, Canada
[4] Univ Western Ontario, Dept Mech Engn, London, ON N6A 5B9, Canada
[5] Univ Western Ontario, Dept Surg, London, ON N6A 3K7, Canada
[6] Univ Western Ontario, Dept Med Biophys, London, ON N6A 3K7, Canada
关键词
ulnar arthroplasty; joint loading; distal radioulnar joint;
D O I
10.1016/j.jbiomech.2005.03.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The development of a novel instrumented implant for ulnar head replacement is presented in this study. This implant was instrumented with strain gauges to quantify bending moments about the anatomic axes of the distal ulna, and subsequently the distal radioulnar joint (DRUJ) reaction force magnitude. The implant was surgically inserted in seven cadaveric upper extremities, which were subsequently mounted in a custom joint simulator. Simulated active unresisted pronation and supination motion trials were conducted using computer-controlled pneumatic actuators to simulate forearm musculature. Passive (unloaded) trials were also conducted. The reaction force across the DRUJ ranged from 2 to I ON in magnitude during this unresisted motion. Increased bending moment magnitudes were measured when the forearm was positioned in supination compared to pronation. The magnitude of joint bending moments showed a consistent pattern with forearm position, regardless of simulated active or passive rotation, or supination and pronation motion trials. This result illustrates that the primary influence on joint load is likely the position and contact with the radial articulation. This study of DRUJ loading should be useful for biomechanical modeling, implant design considerations and improved knowledge of articular mechanics. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1335 / 1341
页数:7
相关论文
共 22 条
[1]
THE LOAD ON THE RADIUS AND ULNA IN DIFFERENT POSITIONS OF THE WRIST AND FOREARM - A CADAVER STUDY [J].
AFEKENSTAM, FW ;
PALMER, AK ;
GLISSON, RR .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03) :363-365
[2]
Experimental investigation of reaction forces at the glenohumeral joint during active abduction [J].
Apreleva, M ;
Parsons, IM ;
Warner, JJP ;
Fu, FH ;
Woo, SLY .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2000, 9 (05) :409-417
[3]
Beckwith T. G., 1993, MECH MEASUREMENTS
[4]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[5]
BOWERS WH, 1992, DISTAL RADIOULNAR JO, P104
[6]
TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[7]
Kinematics of ulnar head arthroplasty [J].
Gordon, KD ;
Dunning, CE ;
Johnson, JA ;
King, GJW .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2003, 28B (06) :551-558
[8]
Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adults [J].
Gordon, KD ;
Pardo, RD ;
Johnson, JA ;
King, GJW ;
Miller, TA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (01) :208-213
[9]
Influence of the pronator quadratus and supinator muscle load on DRUJ stability [J].
Gordon, KD ;
Dunning, CE ;
Johnson, JA ;
King, GJW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (06) :943-950
[10]
An anthropometric study of the distal ulna: Implications for implant design [J].
Gordon, KD ;
Roth, SE ;
Dunning, CE ;
Johnson, JA ;
King, GJW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (01) :57-60