Human tracheobronchial deposition and effect of a cholinergic aerosol inhaled by extremely slow inhalations

被引:8
作者
Anderson, M [1 ]
Svartengren, M
Camner, P
机构
[1] Karolinska Inst, Inst Environm Med, Div Inhalat Toxicol, S-17177 Stockholm, Sweden
[2] Karolinska Hosp, Dept Hlth Sci, Div Occupat Med, S-10401 Stockholm, Sweden
关键词
particle deposition; small airways (broncihioles); cholinergic aerosols; airway resistance;
D O I
10.1080/019021499270231
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Ten subjects inhaled the same amounts of cholinergic aerosol of a mass median diameter (MMD) of 7.7 mu m in a normal provocation test and In a test with extremely slow inhalations (ESI). This new technique using ESI and large droplets/particles gives a high degree of deposition in small ciliated airways which cannot be obtained by using small particles. The purpose was to compare measured effects with calculated doses of the aerosol in large end small ciliated airways. The effect on large airways was measured by airway resistance (R-aw), and the effect on small airways was measured by the phase III slope of single breath nitrogen test (N-2-delta). Mouth and throat deposition was calculated from human experimental data, and deposition of the cholinergic aerosol into large and small airways was calculated, using a computerized lung model. The study showed that the extremely slow inhalation caused a larger effect on R-aw and tendency to a larger effect on N-2-delta compared to the effect in the normal provocation. Deposited dose in the large airways, in percent of inhaled dose, was calculated to be 25-33% for normal inhalation and 20-24% for ESI. Calculated deposited dose ill the small airways (bronchioles; generations 12-16) was 1.8-3.4% for normal inhalation and 18-25% for ESI. For large airways a stronger effect was induced by ESI, perhaps by the more uniform distribution of particles within each generation, compared to normal inhalations when particles deposit near the bifurcations. Concerning the small airways, N-2-delta did not differ significantly between normal and ESI provocations, indicating that they did not react much an cholinergic exposure. We believe that our approach using ESI for small airway deposition of a nebulized aerosol can be of value for estimating the effects of various substances on large and small airways.
引用
收藏
页码:335 / 352
页数:18
相关论文
共 23 条
[1]   Bronchiolar aerosol deposition and clearance [J].
Agnew, JE .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (06) :1118-1122
[2]   HUMAN DEPOSITION AND CLEARANCE OF 6-MU-M PARTICLES INHALED WITH AN EXTREMELY LOW-FLOW RATE [J].
ANDERSON, M ;
PHILIPSON, K ;
SVARTENGREN, M ;
CAMNER, P .
EXPERIMENTAL LUNG RESEARCH, 1995, 21 (01) :187-195
[3]   HUMAN TRACHEOBRONCHIAL DEPOSITION AND EFFECT OF 2 CHOLINERGIC AEROSOLS [J].
ANDERSON, M ;
SVARTENGREN, M ;
DAHLBACK, M ;
NERBRINK, O ;
PHILIPSON, K ;
CAMNER, P .
EXPERIMENTAL LUNG RESEARCH, 1993, 19 (06) :653-669
[4]  
[Anonymous], 1966, HEALTH PHYS, V12, P173
[5]  
BUIST S, 1975, NEW ENGL J MED, V493, P438
[6]  
CAMNER P, 1971, Environmental Physiology, V1, P137
[7]   Human bronchiolar deposition and retention of 6-, 8-, and 10-mu m particles [J].
Camner, P ;
Anderson, M ;
Philipson, K ;
Bailey, A ;
Hashish, A ;
Jarvis, N ;
Bailey, M ;
Svartengren, M .
EXPERIMENTAL LUNG RESEARCH, 1997, 23 (06) :517-535
[8]   THE USE OF LASER DIFFRACTION FOR THE EVALUATION OF THE AEROSOL CLOUDS GENERATED BY MEDICAL NEBULIZERS [J].
CLARK, AR .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1995, 115 (01) :69-78
[9]  
ERICSSON CH, 1995, EUR RESPIR J, V8, P1886, DOI 10.1183/09031936.95.08111886
[10]   Clearance of particles from small ciliated airways [J].
Falk, R ;
Philipson, K ;
Svartengren, M ;
Jarvis, N ;
Bailey, M ;
Camner, P .
EXPERIMENTAL LUNG RESEARCH, 1997, 23 (06) :495-515