Flow injection chemiluminescence analysis of phenolic compounds using the NCS-luminol system

被引:27
作者
Haghighi, B [1 ]
Dadashvand, R [1 ]
机构
[1] Inst Adv Studies Basic Sci, Dept Chem, Zanjan 451951159, Iran
关键词
flow injection; chemiluminescence; NCS; luminol; phenolic compounds;
D O I
10.1007/s00216-005-0267-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A flow injection system coupled with two simple and sensitive chemiluminescence (CL) methods is described for the determination of some phenolic compounds. The methods are based on the inhibition effects of the investigated phenols on the CL signal intensities of N-chlorosuccinimide-KI-luminol (NCS-KI-luminol) and NCS-luminol systems. The influences of the chemical and hydrodynamic parameters on the decrease in CL signal intensities of NCS-KI-luminol and NCS-luminol systems for hydroquinone, catechol, and resorcinol, serving as the model compounds of analyte, were studied in the flow injection mode of analysis. Under the selected conditions, the proposed CL systems were used for the determination of some phenolic compound and analytical characteristics of the systems including calibration equation, correlation coefficient, linear dynamic range, limit of detection, and sample throughput. The limits of detection for hydroquinone, catechol, and resorcinol were 0.002, 0.01, and 0.3 mu M using the NCS-KI-luminol system; for the NCS-luminol system these were 0.01, 0.17, and 1.6 mu M, respectively. The relative standard deviation for 10 repeated measurements of 0.04, 0.06, and 1 mu M of hydroquinone, catechol, and resorcinol were 1.9, 1.4, and 2.0%, respectively, with the NCS-KI-luminol system; for 0.2, 0.5, and 4 mu M of hydroquinone, catechol, and resorcinol these were 2.6, 2.2, and 3.7%, respectively, using the NCS-luminol system. The method was applied to the determination of catechol in known environmental water samples with a relative error of less than 6%. A possible reaction mechanism of the proposed CL system is discussed briefly.
引用
收藏
页码:1246 / 1253
页数:8
相关论文
共 53 条
[1]  
Cui H, 2000, CHEM J CHINESE U, V21, P876
[2]   Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection [J].
Cui, H ;
He, CX ;
Zhao, GW .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :171-179
[3]   Effect of pH on inhibition and enhancement of Luminol-H2O2-Co2+ chemiluminescence by phenolic compounds and amino acids [J].
Cui, H ;
Shi, MJ ;
Meng, R ;
Zhou, J ;
Lai, CZ ;
Lin, XQ .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2004, 79 (03) :233-241
[4]   Determination of phenolic compounds using high-performance liquid chromatography with Ce4+-Tween 20 chemiluminescence detection [J].
Cui, H ;
Zhou, J ;
Xu, F ;
Lai, CZ ;
Wan, GH .
ANALYTICA CHIMICA ACTA, 2004, 511 (02) :273-279
[5]  
DEICHMANN WB, 1981, PATTYS IND HYGIENE A, V2, P2567
[6]   Flow injection chemiluminescence determination of polyhydroxy phenols using luminol-ferricyanide/ferrocyanide system [J].
Du, JX ;
Li, YH ;
Lu, JR .
TALANTA, 2001, 55 (06) :1055-1058
[7]   Simultaneous quantification of jasmonic acid and salicylic acid in plants by vapor-phase extraction and gas chromatography-chemical ionization-mass spectrometry [J].
Engelberth, J ;
Schmelz, EA ;
Alborn, HT ;
Cardoza, YJ ;
Huang, J ;
Tumlinson, JH .
ANALYTICAL BIOCHEMISTRY, 2003, 312 (02) :242-250
[8]  
Flaherty S, 2002, ELECTROPHORESIS, V23, P2327, DOI 10.1002/1522-2683(200207)23:14<2327::AID-ELPS2327>3.0.CO
[9]  
2-K
[10]   TRACE ENRICHMENT OF CHLORINATED PHENOLS FROM DRINKING-WATER ON CHEMICALLY BONDED SORBENTS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FREBORTOVA, J ;
TATARKOVICOVA, V .
ANALYST, 1994, 119 (07) :1519-1523