Diaphragmatic Motion Studied by M-Mode Ultrasonography Methods, Reproducibility, and Normal Values

被引:471
作者
Boussuges, Alain
Gole, Yoann
Blanc, Philippe
机构
[1] Univ Aix Marseille 2, UMR MD 2, P2COE, Marseille, France
[2] Inst Naval Med, Serv Sante Armees, Marseille, France
关键词
diaphragm; gender; sonography; ultrasound; HEMIDIAPHRAGMATIC MOVEMENT; ULTRASOUND; SONOGRAPHY; PNEUMOTACHOGRAPHY; VOLUME;
D O I
10.1378/chest.08-1541
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Although diaphragmatic motion is readily studied by ultrasonography, the procedure remains poorly codified. The aim of this prospective study was to determine the reference values for diaphragmatic motion as recorded by, NI-mode ultrasonography. Methods: Two hundred ten healthy adult subjects (150 men, 60 women) were investigated. Both sides of the posterior diaphragm were identified, and M-mode was used to display the movement of the anatomical structures. Examinations were performed during quiet breathing, voluntary sniffing, and deep breathing. Diaphragmatic excursions were measured from the NI-mode sonographic images. In addition, the reproducibility, (inter- and intra-observer) was assessed. Results: Right and left diaphragmatic motions were successfully assessed during quiet breathing in all subjects. During voluntary sniffing, the measurement was always possible on the right side, and in 208 of 210 volunteers, (in the left side. During deep breathing, air obscuration of the diaphragm by the descending lung was noted in subjects with marked diaphragmatic excursion. Consequently, right diaphragmatic excursion could be measured in 1.95 of 210 subjects, and left diaphragmatic excursion in only 45 subjects. Finally, normal values of both diaphragmatic excursions were determined. Since the excursions were larger in men than in women, the gender should be taken into account. The lower limit values were close to 0.9 cm for women and I cm for men during quiet breathing, 1.6 cm for women and 1.8 cm for men during voluntary sniffing,and 3.7 cm for won-ken and 4.7 cm for men during deep breathing. Conclusions: We demonstrated that M-mode ultrasonography is a reproducible method for assessing hemidiaphragmatic movement.
引用
收藏
页码:391 / 400
页数:10
相关论文
共 20 条
[1]  
Alexander C, 1966, Clin Radiol, V17, P79, DOI 10.1016/S0009-9260(66)80128-9
[2]   Non-invasive quantification of diaphragm kinetics using m-mode sonography [J].
Ayoub, J ;
Cohendy, R ;
Dauzat, M ;
Targhetta, R ;
DeLaCoussaye, JE ;
Bourgeois, JM ;
Ramonatxo, M ;
Prefaut, C ;
Pourcelot, L .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1997, 44 (07) :739-744
[3]  
Ayoub J, 2001, ANESTH ANALG, V92, P755
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   EXCURSION-VOLUME RELATION OF THE RIGHT HEMIDIAPHRAGM MEASURED BY ULTRASONOGRAPHY AND RESPIRATORY AIR-FLOW MEASUREMENTS [J].
COHEN, E ;
MIER, A ;
HEYWOOD, P ;
MURPHY, K ;
BOULTBEE, J ;
GUZ, A .
THORAX, 1994, 49 (09) :885-889
[6]   M-mode sonography of diaphragmatic motion: description of technique and experience in 278 pediatric patients [J].
Epelman, M ;
Navarro, OM ;
Daneman, A ;
Miller, SF .
PEDIATRIC RADIOLOGY, 2005, 35 (07) :661-667
[7]   SONOGRAPHIC MEASUREMENT OF DIAPHRAGMATIC MOTION AFTER CORONARY-ARTERY BYPASS-SURGERY [J].
FEDULLO, AJ ;
LERNER, RM ;
GIBSON, J ;
SHAYNE, DS .
CHEST, 1992, 102 (06) :1683-1686
[8]  
Gerscovich EO, 2001, J ULTRAS MED, V20, P597
[9]   Ultrasound evaluation of the paralyzed diaphragm [J].
Gottesman, E ;
McCool, FD .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (05) :1570-1574
[10]   NORMAL VENTILATORY MOVEMENT OF THE RIGHT HEMIDIAPHRAGM STUDIED BY ULTRASONOGRAPHY AND PNEUMOTACHOGRAPHY [J].
HARRIS, RS ;
GIOVANNETTI, M ;
KIM, BK .
RADIOLOGY, 1983, 146 (01) :141-144