Determination of haloethers in water by solid-phase microextraction

被引:16
作者
Huang, SD
Ting, CY
Lin, CS
机构
[1] Department of Chemistry, National Tsing Hua University
关键词
water analysis; environmental analysis; extraction methods; haloethers;
D O I
10.1016/S0021-9673(96)01102-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A solid-phase microextraction (SPME) technique was used to determine haloethers in water. Three kinds of fibres [100 and 7 mu m polydimethylsiloxane (PDMS) and 85 mu m polyacrylate fibres] were used and compared. The effects of the structure and physical properties of the analytes, sample volume, duration of absorption and desorption, temperature of absorption, carryover, pH, ionic strength and elutropic strength of samples were investigated. It is concluded that the 100 mu m PDMS fibre is the most suitable fibre for the analysis of semi-volatile polar haloethers in water using the SPME technique. This method was applied to environmental samples (tap and lake water) using a simple calibration curve.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 18 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[3]   DETERMINATION OF PHENOLS BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHIC ANALYSIS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (13) :2844-2848
[4]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[5]   DETERMINATION OF VOLATILE CHLORINATED HYDROCARBONS IN AIR AND WATER WITH SOLID-PHASE MICROEXTRACTION [J].
CHAI, M ;
ARTHUR, CL ;
PAWLISZYN, J ;
BELARDI, RP ;
PRATT, KF .
ANALYST, 1993, 118 (12) :1501-1505
[6]   USE OF BONDED PHASE SILICA SORBENTS FOR THE SAMPLING OF PRIORITY POLLUTANTS IN WASTEWATERS [J].
CHLADEK, E ;
MARANO, RS .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (08) :313-320
[7]  
Fawell J.K., 1988, ENV TOXICOLOGY ORGAN
[8]   ONLINE COUPLING OF SOLID-PHASE EXTRACTION AND GAS-CHROMATOGRAPHY WITH ATOMIC-EMISSION DETECTION FOR ANALYSIS OF TRACE POLLUTANTS IN AQUEOUS SAMPLES [J].
HANKEMEIER, T ;
LOUTER, AJH ;
RINKEMA, FD ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1995, 40 (3-4) :119-124
[9]  
LICHTENBERG JJ, 1987, ORGANIC POLLUTANTS W, P70
[10]   DYNAMICS OF ORGANIC-COMPOUND EXTRACTION FROM WATER USING LIQUID-COATED FUSED-SILICA FIBERS [J].
LOUCH, D ;
MOTLAGH, S ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1187-1199