Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault

被引:276
作者
Camacho, Antonio [1 ]
Castilla, Miguel [1 ]
Miret, Jaume [1 ]
Vasquez, Juan C. [2 ]
Alarcon-Gallo, Eduardo [1 ]
机构
[1] Tech Univ Catalonia, Dept Elect Engn, Vilanova I La Geltru 08800, Spain
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Reactive power control; voltage ride through; voltage sag; voltage support; ACTIVE POWER-CONTROL; CONTROL STRATEGIES; PWM RECTIFIER; CONVERTERS; SYNCHRONIZATION; OPERATION; SYSTEMS; DESIGN; SAGS;
D O I
10.1109/TIE.2012.2185016
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Ancillary services for distributed generation (DG) systems become a challenging issue to smartly integrate renewable-energy sources into the grid. Voltage control is one of these ancillary services which can ride through and support the voltage under grid faults. Grid codes from the transmission system operators describe the behavior of the energy source, regulating voltage limits and reactive power injection to remain connected and support the grid under fault. On the basis that different kinds of voltage sags require different voltage support strategies, a flexible control scheme for three-phase grid-connected inverters is proposed. In three-phase balanced voltage sags, the inverter should inject reactive power in order to raise the voltage in all phases. In one-or two-phase faults, the main concern of the DG inverter is to equalize voltages by reducing the negative symmetric sequence and clear the phase jump. Due to system limitations, a balance between these two extreme policies is mandatory. Thus, over-and undervoltage can be avoided, and the proposed control scheme prevents disconnection while achieving the desired voltage support service. The main contribution of this work is the introduction of a control algorithm for reference current generation that provides flexible voltage support under grid faults. Two different voltage sags have been experimentally tested to illustrate the behavior of the proposed voltage support control scheme.
引用
收藏
页码:1429 / 1441
页数:13
相关论文
共 39 条
  • [1] Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
    Alepuz, Salvador
    Busquets-Monge, Sergio
    Bordonau, Josep
    Martinez-Velasco, Juan A.
    Silva, Cesar A.
    Pontt, Jorge
    Rodriguez, Jose
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) : 2162 - 2173
  • [2] Overview of Recent Grid Codes for Wind Power Integration
    Altin, Muefit
    Goeksu, Oemer
    Teodorescu, Remus
    Rodriguez, Pedro
    Jensen, Birgitte-Bak
    Helle, Lars
    [J]. OPTIM 2010: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, PTS I-IV, 2010, : 1152 - +
  • [3] [Anonymous], WHITE PAPTER INTEGRA
  • [4] [Anonymous], 154722008 IEEEE
  • [5] [Anonymous], 2002, 617272002 IEC
  • [6] [Anonymous], NEW ERA EL EUR DISTR
  • [7] [Anonymous], J EOLIEN
  • [8] [Anonymous], FUNCTIONAL SPECIFICA
  • [9] [Anonymous], 21970 EUR EUR COMM
  • [10] [Anonymous], TRENDS PHOT APPL SUR