Biopolymer mass spectrometer with cryogenic particle detectors

被引:47
作者
Twerenbold, D
机构
[1] Institut de Physique, Université Neuchâtel, CH-2000 Neuchâtel
关键词
D O I
10.1016/0168-9002(95)01102-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel type of biopolymer mass spectrometer is proposed for massive proteins, polypeptides and DNA-fragments by replacing standard ionizing detectors with cryogenic particle detectors. The detection efficiency in ionizing detectors decreases rapidly with increasing biopolymer mass owing to the biopolymer's decreasing velocity. Cryogenic particle detectors, however, record the total kinetic energy deposited by the accelerated biopolymer. In a given electric acceleration field, this kinetic energy is independent of mass and depends only on the biopolymer's charged stare. Using the intrinsic properties of cryogenic particle detectors and their specific fabrication techniques, a mass spectrometer has been designed specifically for high-throughput DNA-sequencing. The calculated DNA-fragment separation rate would be increased by several orders of magnitude as compared to standard gel-electrophoresis DNA-sequencers.
引用
收藏
页码:253 / 255
页数:3
相关论文
共 12 条
[1]  
CHEN CH, 1993, SPIE, V1891, P94
[2]   WHOLE-GENOME RANDOM SEQUENCING AND ASSEMBLY OF HAEMOPHILUS-INFLUENZAE RD [J].
FLEISCHMANN, RD ;
ADAMS, MD ;
WHITE, O ;
CLAYTON, RA ;
KIRKNESS, EF ;
KERLAVAGE, AR ;
BULT, CJ ;
TOMB, JF ;
DOUGHERTY, BA ;
MERRICK, JM ;
MCKENNEY, K ;
SUTTON, G ;
FITZHUGH, W ;
FIELDS, C ;
GOCAYNE, JD ;
SCOTT, J ;
SHIRLEY, R ;
LIU, LI ;
GLODEK, A ;
KELLEY, JM ;
WEIDMAN, JF ;
PHILLIPS, CA ;
SPRIGGS, T ;
HEDBLOM, E ;
COTTON, MD ;
UTTERBACK, TR ;
HANNA, MC ;
NGUYEN, DT ;
SAUDEK, DM ;
BRANDON, RC ;
FINE, LD ;
FRITCHMAN, JL ;
FUHRMANN, JL ;
GEOGHAGEN, NSM ;
GNEHM, CL ;
MCDONALD, LA ;
SMALL, KV ;
FRASER, CM ;
SMITH, HO ;
VENTER, JC .
SCIENCE, 1995, 269 (5223) :496-512
[3]   DIRECT OBSERVATION OF A DNA QUADRUPLEX BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY [J].
GOODLETT, DR ;
CAMP, DG ;
HARDIN, CC ;
CORREGAN, M ;
SMITH, RD .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (03) :181-183
[4]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[5]  
Linhard J, 1961, PHYS REV, V124, P128
[6]  
MAXAM AM, 1977, P NATL ACAD SCI USA, V74, P1258
[7]   DNA SEQUENCING WITH CHAIN-TERMINATING INHIBITORS [J].
SANGER, F ;
NICKLEN, S ;
COULSON, AR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1977, 74 (12) :5463-5467
[8]   SEPARATION OF YEAST CHROMOSOME-SIZED DNAS BY PULSED FIELD GRADIENT GEL-ELECTROPHORESIS [J].
SCHWARTZ, DC ;
CANTOR, CR .
CELL, 1984, 37 (01) :67-75
[9]   MASS-SPECTROMETRY OF MACROMOLECULES - HAS ITS TIME NOW COME [J].
SENKO, MW ;
MCLAFFERTY, FW .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 1994, 23 :763-785
[10]  
TWERENBOLD D, 1995, IN PRESS REP PROG PH