Reproducibility of in vivo metabolite quantification with proton magnetic resonance spectroscopic Imaging

被引:41
作者
Chard, DT [1 ]
McLean, MA [1 ]
Parker, GJM [1 ]
MacManus, DG [1 ]
Miller, DH [1 ]
机构
[1] UCL, Inst Neurol, NMR Res Unit, London WC1N 3BG, England
关键词
magnetic resonance spectroscopy; metabolite quantification; reproducibility; in vivo; brain; human intra-and inter scanner;
D O I
10.1002/jmri.10043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate intra- and interscanner in vivo reproducibility of brain metabolite quantification using (1)H magnetic resonance spectroscopic imaging ((1)H-MRSI) (PRESS localization, TE = 30 msec, voxel volume = 2.3 rnL) and the linear combination model (LCModel). Materials and Methods: One subject had a total of nine scans on three occasions at a single site, and three subjects had single scans at two sites. Coefficients of variation (CVs) were estimated using different statistical models applied to intra- and interscanner data; therefore, only qualitative comparisons may be made between results. Results: : CV (intra-/interscanner) for metabolite quantifications were choline, 12.3%/10.1%; creatine, 9.9%/10.6%; glutamate + glutamine, 15.8%/13.6%; myo-inositol, 18.5%/14.7%; and N-acetyl-aspartate + N-acetyl-aspartyl-glutamate, 6.1%/7.0%. Overall, total intra- and intersubject variability was greater than intra- and interscanner variability. Conclusion: When quantifying metabolic concentrations using the methods employed in this study, biological factors contribute a greater proportion to measurement variability than measurement errors. Using this technique, intra- and intersite measurement errors are of the same order.
引用
收藏
页码:219 / 225
页数:7
相关论文
共 24 条
[1]   Multimodal image coregistration and partitioning - A unified framework [J].
Ashburner, J ;
Friston, K .
NEUROIMAGE, 1997, 6 (03) :209-217
[2]   Voxel-based morphometry - The methods [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2000, 11 (06) :805-821
[3]  
Barker PB, 2000, MAGN RESON MED, V43, P348, DOI 10.1002/(SICI)1522-2594(200003)43:3<348::AID-MRM5>3.0.CO
[4]  
2-M
[5]   Measurement error and correlation coefficients [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7048) :41-42
[6]  
Bland JM, 1996, BRIT MED J, V313, P744
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]  
Brooks WM, 1999, MAGNET RESON MED, V41, P193, DOI 10.1002/(SICI)1522-2594(199901)41:1<193::AID-MRM27>3.0.CO
[9]  
2-P
[10]   Reproducibility of high spatial resolution proton magnetic resonance spectroscopic imaging in the human brains [J].
Charles, HC ;
Lazeyras, F ;
Tupler, LA ;
Krishnan, KRR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (04) :606-610