Dielectric resonance phenomena in ultra high field MRI

被引:70
作者
Kangarlu, A
Baertlein, BA
Lee, R
Ibrahim, TS
Yang, LN
Abduljalil, AM
Robitaille, EML
机构
[1] Ohio State Univ, MRI Facil, Dept Radiol, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Elect Engn, Columbus, OH 43210 USA
关键词
magnetic resonance imaging; artifacts; ultra high frequency; dielectric resonance; image quality;
D O I
10.1097/00004728-199911000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Dielectric resonances have previously been advanced as a significant cause of image degradation at higher fields. In this work, a study of dielectric resonances in ultra high field MRI is presented to explore the real importance of dielectric resonances in the human brain in this setting. Method: Gradient-recalled echo images were acquired using a transverse electromagnetic resonator at 1.5, 4.7, and 8 T. Images were obtained from the human head and from phantoms filled with pure water, saline, and mineral oil. In addition, an exact theoretical analysis of dielectric resonances is presented for a spherical phantom and for a model of the human head. Results: Theoretical results demonstrate that distilled water can sustain dielectric resonances in head-sized spheres near 200 and 360 MHz, but the presence of significant conductivity suppresses these resonances. These findings are confirmed experimentally with proton images of water and saline (0.05 sand 0.125 M NaCl). For lossy phantoms, coupling between the source and phantom overwhelms the dielectric resonance. Because of their low relative permittivity, mineral oil phantoms with 20 cm diameter do not exhibit dielectric resonances below similar to 900 MHz. Significant dielectric resonances were not observed in human head images obtained at 1.5, 4.7, and 8 T. Conclusion: It appears that dielectric resonances do not have any real importance in determining image quality for MR studies of the human head. It is advanced that RF coils are much more likely to be the source of any inhomogeneity.
引用
收藏
页码:821 / 831
页数:11
相关论文
共 34 条
[1]   Acquisition of human multislice MR images at 8 Tesla [J].
Abduljalil, AM ;
Kangarlu, A ;
Zhang, XL ;
Burgess, RE ;
Robitaille, PML .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) :335-340
[2]  
Barfuss H, 1990, NMR Biomed, V3, P31, DOI 10.1002/nbm.1940030106
[3]   POWER DEPOSITION IN WHOLE-BODY NMR IMAGING [J].
BOTTOMLEY, PA ;
EDELSTEIN, WA .
MEDICAL PHYSICS, 1981, 8 (04) :510-512
[4]   THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION [J].
CHEN, CN ;
SANK, VJ ;
COHEN, SM ;
HOULT, DI .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :722-729
[5]   The dielectric properties of biological tissues .1. Literature survey [J].
Gabriel, C ;
Gabriel, S ;
Corthout, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2231-2249
[6]   ELECTROMAGNETIC RESONANCES OF FREE DIELECTRIC SPHERES [J].
GASTINE, M ;
COURTOIS, L ;
DORMANN, JL .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1967, MT15 (12) :694-+
[7]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[8]   SENSITIVITY OF THE ZEUGMATOGRAPHIC EXPERIMENT INVOLVING HUMAN SAMPLES [J].
HOULT, DI ;
LAUTERBUR, PC .
JOURNAL OF MAGNETIC RESONANCE, 1979, 34 (02) :425-433
[9]  
IBRAHIM RS, 1998, INT SOC MAGN RES MED, P652
[10]   Computation of electromagnetic fields for high-frequency magnetic resonance imaging applications [J].
Jin, JM ;
Chen, J ;
Chew, WC ;
Gan, H ;
Magin, RL ;
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2719-2738