Comparison of susceptibility testing methods with mecA gene analysis for determining oxacillin (methicillin) resistance in clinical isolates of Staphylococcus aureus and coagulase-negative Staphylococcus spp.

被引:67
作者
Kohner, P [1 ]
Uhl, J [1 ]
Kolbert, C [1 ]
Persing, D [1 ]
Cockerill, F [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Div Clin Microbiol, Bacteriol Lab, Rochester, MN 55905 USA
关键词
D O I
10.1128/JCM.37.9.2952-2961.1999
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Ninety-nine clinical staphylococcal isolates (58 coagulase-negative Staphylococcus spp, [CoNS] and 41 Staphylococcus aureus isolates) were evaluated for susceptibility to oxacillin, The following susceptibility testing methods, media, and incubation conditions mere studied: agar dilution by using Mueller-Hinton (MH) medium (Difco) supplemented with either 0, 2, or 4% NaCl and incubation at 30 or 35 degrees C in ambient air for 24 or 48 hf dish diffusion by using commercially prepared MH medium (Difco) and MN II, agar (BBL) and incubation at 35 degrees C in ambient air for 24 or 48 h; and agar screen (spot or swab inoculation) by using commercially prepared agar (Remel) or MH agar (Difco) prepared in-house, each containing 4% NaCl and 6 mu g of oxacillin/ml (0.6-mu g/ml oxacillin was also studied with MH agar prepared in-house for the agar swab method and CoNS isolates) and incubation at 35 degrees C in ambient air for 24 or 48 h for swab inoculation and at 30 or 35 degrees C in ambient air for 24 or 48 h for spot inoculation. The results for these methods were compared to the results for mecA gene detection by a PCR method. Given the ability to support growth and the results for susceptibility testing (the breakpoint for susceptible isolates was less than or equal to 2 mu g/ml), the best methods for CoNS isolates were (i) agar dilution by using MH medium supplemented with 4% NaCl and incubation at 35 degrees C for 48 h (no growth failures were noted, and sensitivity was 97.6%) and (ii) agar screen (swab inoculation) by using MH medium prepared in-house supplemented with 4% NaCl and containing 0.6 mu g oxacillin/ml and incubation at 35 degrees C for 48 h tone isolate that did not carry the mecA gene did not grow, and the sensitivity was 100%), All but one (agar dilution without added NaCl and incubation at 30 degrees C for 48 h) of the methods tested revealed all oxacillin-resistant S. aureus isolates, and no growth failures occurred with any method. If the breakpoint For susceptibility was lowered to less than or equal to 1 mu g/ml for agar dilution methods, more CoNS isolates with oxacillin resistance related to the mecA gene were detected when 0 or 2% NaCl agar supplementation was used, Only one CoNS isolate with mecA gene-associated resistance was not detected by using agar dilution and MH medium supplemented with 4% NaCl with incubation for 48 h. When the breakpoint for susceptibility was decreased 10-fold (from 6,0 to 0.6 mu g of oxacillin per mi) for the agar swab screen method, fully 100% of the CoNS isolates that carried the mecA gene were identified.
引用
收藏
页码:2952 / 2961
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 1999, M100S9 NAT COMM CLIN
[2]   OPTIMIZING TESTING OF METHICILLIN-RESISTANT STAPHYLOCOCCUS SPECIES [J].
BAKER, CN ;
HUANG, MB ;
TENOVER, FC .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1994, 19 (03) :167-170
[3]   Evaluation of Alamar colorimetric broth microdilution susceptibility testing method for staphylococci and enterococci [J].
Baker, CN ;
Tenover, FC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (11) :2654-2659
[4]  
CHAMBERS HF, 1992, METHICILLIN RESISTAN, P21
[5]   EVALUATION OF LABORATORY TESTS FOR DETECTION OF METHICILLIN-RESISTANT STAPHYLOCOCCUS-AUREUS AND STAPHYLOCOCCUS-EPIDERMIDIS [J].
COUDRON, PE ;
JONES, DL ;
DALTON, HP ;
ARCHER, GL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 24 (05) :764-769
[6]   Comparison of ATB Staph, Rapid ATB Staph, Vitek, and E-test methods for detection of oxacillin heteroresistance in staphylococci possessing mecA [J].
Frebourg, NB ;
Nouet, D ;
Lemée, L ;
Martin, E ;
Lemeland, JF .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (01) :52-57
[7]   MULTIPLEX PCR FOR IDENTIFICATION OF METHICILLIN-RESISTANT STAPHYLOCOCCI IN THE CLINICAL LABORATORY [J].
GEHA, DJ ;
UHL, JR ;
GUSTAFERRO, CA ;
PERSING, DH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (07) :1768-1772
[8]   SCREENING METHOD FOR RAPID DETECTION OF METHICILLIN-RESISTANT (HETERORESISTANT) STAPHYLOCOCCUS-AUREUS [J].
HANSEN, SL ;
POPE, WA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (05) :886-887
[9]   EFFECT OF THE SOURCE OF MUELLER-HINTON AGAR AND RESISTANCE FREQUENCY ON THE DETECTION OF METHICILLIN-RESISTANT STAPHYLOCOCCUS-AUREUS [J].
HINDLER, JA ;
INDERLIED, CB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 21 (02) :205-210
[10]   EFFECT OF SOURCE OF MUELLER-HINTON AGAR ON DETECTION OF OXACILLIN RESISTANCE IN STAPHYLOCOCCUS-AUREUS USING A SCREENING METHODOLOGY [J].
HINDLER, JA ;
WARNER, NL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (04) :734-735