Postural arm control following cervical spinal cord injury

被引:10
作者
Perreault, EJ [1 ]
Crago, PE
Kirsch, RF
机构
[1] Northwestern Univ, Sch Med, Dept Physiol, Chicago, IL 60611 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Louis Stokes VA Med Ctr, Cleveland, OH 44106 USA
基金
美国国家卫生研究院;
关键词
endpoint stiffness; functional neuromuscular stimulation; posture stability; spinal cord injury;
D O I
10.1109/TNSRE.2001.1000117
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study used estimates of dynamic endpoint stiffness to quantify postural arm stability following cervical spinal cord injury (SCI) and to investigate how this stability was affected by functional neuromuscular stimulation (FNS). Measurements were made in the horizontal plane passing through the glenohumeral joint on three SCI-impaired arms, which ranged in functional level from a weak C5 to a strong C6. Endpoint stiffness, which characterizes the relationship between externally imposed hand displacements and the resultant forces, was estimated during the application of planar, stochastic perturbations to each arm. These estimates were used in conjunction with voluntary endpoint force measurements to quantify stability and strength during voluntary contractions and during voluntary contractions in the presence of triceps FNS. The primary findings were: 1) the differences in the force generating capabilities of these arms were due primarily to differences in shoulder strength; 2) measurements of strength alone could not be used to predict arm stability; and 3) triceps FNS improved postural arm stability for all tested conditions. These results suggest strategies for improved control of FNS systems designed to restore arm function following cervical SCI and underscore the importance of examining the effects of FNS on both strength and stability.
引用
收藏
页码:369 / 377
页数:9
相关论文
共 35 条
[1]   A robotic manipulator for the characterization of two-dimensional dynamic stiffness using stochastic displacement perturbations [J].
Acosta, AM ;
Kirsch, RF ;
Perreault, EJ .
JOURNAL OF NEUROSCIENCE METHODS, 2000, 102 (02) :177-186
[2]  
Agarwal G. C., 1977, Transactions of the ASME. Series K, Journal of Biomechanical Engineering, V99, P166, DOI 10.1115/1.3426285
[3]  
American Spinal Injury Association/International Medical Society of Paraplegia, 1992, STAND NEUR FUNCT CLA
[4]  
[Anonymous], 1978, ANAL PHYSL SYSTEMS
[5]  
[Anonymous], 1978, SHOULDER NECK
[6]   Electrically stimulated elbow extension in persons with C5/C6 tetraplegia: A functional and physiological evaluation [J].
Bryden, AM ;
Memberg, WD ;
Crago, PE .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (01) :80-88
[7]  
Crago P E, 1998, IEEE Trans Rehabil Eng, V6, P1, DOI 10.1109/86.662614
[8]   FEEDBACK-REGULATION OF HAND GRASP OPENING AND CONTACT FORCE DURING STIMULATION OF PARALYZED MUSCLE [J].
CRAGO, PE ;
NAKAI, RJ ;
CHIZECK, HJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (01) :17-28
[9]  
DEMAGONE D, 1991, J AM PARAPLEGIA SOC, V14, P95
[10]   DYNAMIC AND LOADED IMPEDANCE COMPONENTS IN THE MAINTENANCE OF HUMAN ARM POSTURE [J].
DOLAN, JM ;
FRIEDMAN, MB ;
NAGURKA, ML .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1993, 23 (03) :698-709