Sampling error in US field crop unit process data for life cycle assessment

被引:9
作者
Cooper, Joyce Smith [1 ]
Kahn, Ezra [1 ]
Ebel, Robert [2 ]
机构
[1] Univ Washington, Design Environm Lab, Seattle, WA 98195 USA
[2] USDA, Econ Res Serv, Washington, DC 20024 USA
关键词
Error; Inventory data; Life cycle assessment; Meta data; Parameterization; Uncertainty;
D O I
10.1007/s11367-012-0454-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The research presented here was motivated by an interest in understanding the magnitude of sampling error in crop production unit process data developed for life cycle assessments (LCAs) of food, biofuel, and bioproduct production. More broadly, uncertainty data are placed within the context of conclusive interpretations of comparative bioproduct LCA results. Data from the US Department of Agriculture's Agricultural Resource Management Survey were parameterized for 466 crop-state-year combinations, using 146 variables representing the previous crop, tillage and seed operations, irrigation, and applications of synthetic fertilizer, lime, nitrogen inhibitor, organic fertilizer, and pesticides. Data are described by Student's t distributions representing sampling error through the relative standard error (RSE) and are organized by the magnitude of the RSE by data point. Also, instances in which the bounds of the 95 % confidence intervals are less than zero or exceed actual limits are identified. Although the vast majority of the data have a RSE less than 100 %, values range from 0 to 1,600 %. The least precision was found in data collected between 2001 and 2002, in the production of corn and soybeans and in synthetic and pesticide applications and irrigation data. The highest precision was seen in the production of durum wheat, rice, oats, and peanuts and in data representing previous crops and till and seed technology use. Additionally, upwards of 20 % of the unit process, data had 95 % confidence intervals that are less than or exceed actual limits, such as an estimation of a negative area or a portion exceeding a total area, as a consequence of using a jackknife on subsets of data for which the weights are not calibrated explicitly and a low presence of certain practices. High RSE values arise from the RSE representing a biased distribution, a jackknife estimate being nearly zero, or error propagation using low-precision data. As error propagates to the final unit process data, care is required when interpreting an inventory, e.g., Monte Carlo simulation should only be sampled within the appropriate bounds. At high levels of sampling error such as those described here, comparisons of LCA bioproduct results must be made with caution and must be tested to ensure mean values are different to a desired level of significance.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 10 条
  • [1] Parameterization in Life Cycle Assessment inventory data: review of current use and the representation of uncertainty
    Cooper, Joyce Smith
    Noon, Michael
    Kahn, Ezra
    [J]. INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2012, 17 (06) : 689 - 695
  • [2] Dieck R.H., 2007, MEASUREMENT UNCERTAI
  • [3] Dubman R.W., 2000, Variance Estimation with USDA's Farm Costs and Returns Surveys and Agricultural Resource Management Study Surveys
  • [4] Kim C. S., 2004, Agricultural and Resource Economics Review, V33, P293
  • [5] Characterizing, propagating, and analyzing uncertainty in life-cycle assessment - A survey of quantitative approaches
    Lloyd, Shannon M.
    Ries, Robert
    [J]. JOURNAL OF INDUSTRIAL ECOLOGY, 2007, 11 (01) : 161 - 179
  • [6] Sommer JE, 1998, 1995 20 ANN FAM FARM
  • [7] Spiegel M. R., 2009, SCHAUMS OUTLINES PRO
  • [8] USDA, 2011, 2007 CENS AGR HIST 7, V2
  • [9] Weidema B, 2011, Ecoinvent report 1
  • [10] Weidema BoPedersen., 1996, Journal of Cleaner Production, V4, P167, DOI [DOI 10.1016/S0959-6526(96)00043-1, 10.1016/S0959-6526, DOI 10.1016/S0959-6526]