Objectives: To assess, in acutely ill asthmatic children, the feasibility of obtaining reproducible measurements of two independent lung function tests, namely spirometry and respiratory resistance, using the forced oscillation technique (Rfo). Design/setting: A prospective observational study of 150 previously untrained children, aged 2 to 17 years, treated for acute asthma in a tertiary-care pediatric emergency department. Measurements: Following a standardized physical examination, three measurements of respiratory resistance by forced oscillation were attempted at 8 Hz (Rfo(8)) and at 16 Hz (Rfo(16)), followed by spirometry, all using the same instrument (Gusto Vit R; Gusto Med; Munich, Germany). Results: On the initial assessment, 98 (65%) children, aged 2 to 17 years, were able to reproducibly perform the Rfo(8) measurement, 77 (51%) were able to reproducibly perform the Rfo(16) measurement, while only 65 (43%) subjects managed to reliably pet-form spirometry. A notable proportion of preschool-aged children cooperated with the Rfo, technique: 19% of 3-year-olds, 40% of year-olds, and 83% of 5-year-olds, The superior success rate with Rfo(8) as compared with spirometry was seen in all age groups but was most striking both in preschoolers (relative risk [RR] = 10.5; 95% confidence interval [CI], 8.0 to 13.8) and in children aged 6 to 9 years (RR = 1.28; 95% CI, 1.18 to 1.39), Rfo(8) values correlated significantly with clinical markers of asthma severity such as respiratory rate (r = 0.38) and heart rate (r = 0.23) as well as with FEV, values (r(2) = 0.73). Conclusions: This study demonstrates the feasibility of obtaining reproducible measurements of respiratory resistance in a notable proportion of untrained, acutely ill, asthmatic children, The forced oscillation technique appears as an attractive alternative to objectively assess lung function in children too young or too ill to cooperate with spirometry.
引用
收藏
页码:1519 / 1525
页数:7
相关论文
共 45 条
[1]  
ALLEN JL, 1993, AM REV RESPIR DIS, V147, P474
[2]  
[Anonymous], 1987, AM REV RESPIR DIS, V136, P225
[3]   LUNG-FUNCTION TESTING - SELECTION OF REFERENCE VALUES AND INTERPRETATIVE STRATEGIES [J].
不详 .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (05) :1202-1218
[4]  
[Anonymous], 1987, Am Rev Respir Dis, V136, P1285
[5]  
Barleben A, 1990, Pneumologie, V44, P950
[6]   COMBINED SALBUTAMOL AND IPRATROPIUM BROMIDE BY INHALATION IN THE TREATMENT OF SEVERE ACUTE ASTHMA [J].
BECK, R ;
ROBERTSON, C ;
GALDESSEBALDT, M ;
LEVISON, H .
JOURNAL OF PEDIATRICS, 1985, 107 (04) :605-608
[7]  
Berdel D, 1989, Pneumologie, V43, P392
[8]   MECHANICAL CONSEQUENCES OF AIRWAY SMOOTH MUSCLE RELAXATION [J].
BOUHUYS, A ;
VANDEWOE.K .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 30 (05) :670-&
[9]   EVALUATION OF THE INTERRUPTER TECHNIQUE FOR THE USE OF ASSESSING AIRWAY-OBSTRUCTION IN CHILDREN [J].
CARTER, ER ;
STECENKO, AA ;
POLLOCK, BH ;
JAEGER, MJ .
PEDIATRIC PULMONOLOGY, 1994, 17 (04) :211-217
[10]   EVALUATION OF A TIDAL EXPIRATORY FLOW INDEX IN HEALTHY AND DISEASED INFANTS [J].
CLARKE, JR ;
ASTON, H ;
SILVERMAN, M .
PEDIATRIC PULMONOLOGY, 1994, 17 (05) :285-290