The effect of gel lubrication on cuff leakage of double lumen tubes during thoracic surgery

被引:13
作者
Sanjay, PS [1 ]
Miller, SA [1 ]
Corry, PR [1 ]
Russell, GN [1 ]
Pennefather, SH [1 ]
机构
[1] Ctr Cardiothorac, Dept Anaesthesia, Liverpool L14 3PE, Merseyside, England
关键词
D O I
10.1111/j.1365-2044.2005.04440.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
High-volume, low-pressure tracheal cuffs of disposable double lumen tubes may offer limited protection to the dependent lung if fluid leaks through folds in the inflated cuffs. This study was undertaken to determine the incidence of fluid leakage past the tracheal cuff and whether gel lubrication reduces the incidence. Fifty-five patients were randomly assigned to receive a double lumen tube with or without gel lubrication. The dependent lung was intubated. With the patient in the lateral position, methylthionium chloride was administered above the tracheal cuff via a pre-attached catheter. Fibreoptic bronchoscopy was performed to determine if dye had passed the tracheal cuff. Three patients were excluded. Dye leakage was seen in 12/27 and 3/25 patients in the unlubricated and lubricated group, respectively (p = 0.014). Gel lubrication significantly reduces fluid leakage past the tracheal cuff of a double lumen tube and should be considered for all thoracic surgical patients requiring one-lung ventilation.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 16 条
[1]   Gastroesophageal reflux and tracheal aspiration in the thoracotomy position: Should ranitidine premedication be routine? [J].
Agnew, NM ;
Kendall, JB ;
Akrofi, M ;
Tran, J ;
Soorae, AS ;
Page, R ;
Russell, GN ;
Pennefather, SH .
ANESTHESIA AND ANALGESIA, 2002, 95 (06) :1645-1649
[2]   ADJUSTMENT OF INTRACUFF PRESSURE TO PREVENT ASPIRATION [J].
BERNHARD, WN ;
COTTRELL, JE ;
SIVAKUMARAN, C ;
PATEL, K ;
YOST, L ;
TURNDORF, H .
ANESTHESIOLOGY, 1979, 50 (04) :363-366
[3]   Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration [J].
Blunt, MC ;
Young, PJ ;
Patil, A ;
Haddock, A .
ANESTHESIOLOGY, 2001, 95 (02) :377-381
[4]   Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes [J].
Brodsky, JB ;
Macario, A ;
Mark, JBD .
ANESTHESIA AND ANALGESIA, 1996, 82 (04) :861-864
[5]  
BUNEGIN L, 1993, ANESTH ANALG, V76, P1083
[6]   PREVENTION OF HOSPITAL-ACQUIRED PNEUMONIA - MEASURING EFFECT IN OUNCES, POUNDS, AND TONS [J].
CRAVEN, DE .
ANNALS OF INTERNAL MEDICINE, 1995, 122 (03) :229-231
[7]  
JESSEPH JE, 1957, SURG GYNECOL OBSTET, V105, P210
[8]   PRESSURE ON THE TRACHEAL MUCOSA FROM CUFFED TUBES [J].
LEIGH, JM ;
MAYNARD, JP .
BRITISH MEDICAL JOURNAL, 1979, 1 (6172) :1173-1174
[9]  
MEHTA S, 1984, ANN ROY COLL SURG, V66, P356
[10]   COMPLICATIONS OF SURGERY IN THE TREATMENT OF CARCINOMA OF THE LUNG [J].
NAGASAKI, F ;
FLEHINGER, BJ ;
MARTINI, N .
CHEST, 1982, 82 (01) :25-29