Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur

被引:93
作者
Krettek, C [1 ]
Müller, M
Miclau, T
机构
[1] Hannover Med Sch, Trauma Dept, D-30623 Hannover, Germany
[2] AO Documentat, CH-7270 Davos, Switzerland
[3] Univ Calif San Francisco, San Francisco Gen Hosp, Dept Orthopaed Surg, San Francisco, CA 94110 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2001年 / 32卷
关键词
minimally invasive osteosynthesis; percutaneous plate osteosynthesis; MIPO; MIPPO; supracondylar femoral fracture; submuscular plating;
D O I
10.1016/S0020-1383(01)00180-2
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Problems with conventional open reduction and internal plate fixation of distal femoral fractures are well established. These problems have been associated with extensile exposures of the fracture site. "Biological plating", like intramedullary nail fixation, of distal. femoral fractures preserves the soft tissues about the fracture, and is associated with early fracture consolidation and low rates of infection. Anatomical restoration of the articular surface continues to be the main goal in the treatment of these fractures regardless of the stabilization technique. Submuscular plating techniques, which provide for closed reduction of the diaphyseal /metaphyseal component of the fracture, have improved significantly.
引用
收藏
页码:14 / 23
页数:10
相关论文
共 59 条
[1]
BELLATTI J, 2001, AAOS 2001 ANN M SAN
[2]
The results of open reduction and internal fixation of distal femur fractures using a biologic (Indirect) reduction technique [J].
Bolhofner, BR ;
Carmen, B ;
Clifford, P .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (06) :372-377
[3]
CHIRON HS, 1974, CLIN ORTHOP RELAT R, P160
[4]
CLOSED REDUCTION AND EARLY CAST-BRACE AMBULATION IN TREATMENT OF FEMORAL FRACTURES .2. RESULTS IN 143 FRACTURES [J].
CONNOLLY, JF ;
DEHNE, E ;
LAFOLLETTE, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1581-1599
[5]
Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique? [J].
Farouk, O ;
Krettek, C ;
Miclau, T ;
Schandelmaier, P ;
Guy, P ;
Tscherne, H .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (06) :401-406
[6]
Effects of percutaneous and conventional plating techniques on the blood supply to the femur [J].
Farouk, O ;
Krettek, C ;
Miclau, T ;
Schandelmaier, P ;
Tscherne, H .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1998, 117 (08) :438-441
[7]
FAROUK O, 1997, INJURY S1, V28, P7
[8]
SUPRACONDYLAR-INTERCONDYLAR FRACTURES OF THE FEMUR TREATED WITH A SUPRACONDYLAR PLATE AND LAG SCREW [J].
GILES, JB ;
DELEE, JC ;
HECKMAN, JD ;
KEEVER, JE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (06) :864-870
[9]
2-PLANE FIXATION OF ACUTE SUPRACONDYLAR AND INTRACONDYLAR FRACTURES OF FEMUR [J].
HALL, MF .
SOUTHERN MEDICAL JOURNAL, 1978, 71 (12) :1474-1480
[10]
HEALY WL, 1983, CLIN ORTHOP RELAT R, P166