A high-temperature furnace for X-ray diffraction with directly machined α-Al2O3 ceramic parts

被引:14
作者
Estermann, M [1 ]
Reifler, H [1 ]
Steurer, W [1 ]
Filser, F [1 ]
Kocher, P [1 ]
Gauckler, LJ [1 ]
机构
[1] ETH Zurich, Lab Kristallog, CH-8092 Zurich, Switzerland
关键词
D O I
10.1107/S0021889899006032
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A complex high-temperature furnace has been produced from presintered alpha-Al2O3 precompacts. The furnace is designed for the Mar345 imaging-plate detector system. Up to now, the design complexity of ceramic parts has been limited by the difficulty of machining hard ceramic materials or by the moulds used in hot-pressing and casting. However, the machining of soft presintered ceramic materials enables the realisation of much more demanding designs, provided that the final sintering shrinkage of the ceramic is homogeneous and predictable. The design of the furnace and its realisation and application in an X-ray diffraction study with synchrotron radiation are presented.
引用
收藏
页码:833 / 836
页数:4
相关论文
共 8 条
[1]  
*CATIA SOL, 1996, COMP AID 3 DIM INT A
[2]  
*CRC, 1986, CRC HDB CHEM PHYS
[3]   Diffuse scattering data acquisition techniques [J].
Estermann, MA ;
Steurer, W .
PHASE TRANSITIONS, 1998, 67 (01) :165-195
[4]  
Filser F, 1998, MAT MED, P165
[5]  
Filser F., 1997, BIOCERAMICS, V10, P433
[6]  
Munro RG, 1997, J AM CERAM SOC, V80, P1919, DOI 10.1111/j.1151-2916.1997.tb03074.x
[7]   High-temperature furnace for an imaging-plate data-acquisition system [J].
Schreuer, J ;
Baumgarte, A ;
Estermann, MA ;
Steurer, W ;
Reifler, H .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1996, 29 :365-370
[8]  
*XRAY RES GMBH, 1999, IM PLAT DET SYST 345