Three-dimensional T1 mapping for dGEMRIC at 3.0 T using the look locker method

被引:68
作者
Kimelman, T
Vu, A
Storey, P
McKenzie, C
Burstein, D
Prasad, P
机构
[1] Evanston NW Healthcare, Dept Radiol, Evanston, IL USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL USA
[3] GE Healthcare, Evanston, IL USA
[4] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[5] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
look locker; cartilage; T1; mapping;
D O I
10.1097/01.rli.0000195842.49255.ea
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Objective: The objective of this study was to implement a three-dimensional (3-D) T1 mapping sequence (3DLL) at 3.0 T for dGEMRIC based on the Look Locker scheme. Materials and Methods: Because all current reports on dGEMRIC are at 1.5 T and mostly using 2-D IR fast spin echo (FSE), data were acquired at 1.5 T and 3.0 T with both 3DLL and 2-D IR-FSE sequence. Phantoms with different concentrations of Gd(DTPA)2were used and seven subjects (three asymptornatic, four symptomatic) were scanned using the dGEMRIC technique. Results: The T1 measurements obtained on the phantom with 3DLL show very good agreement with those acquired with 2-D IR-FSE. Using a two-tailed paired t test, the TI (Gd) measurements in two sections obtained in all subjects with both sequences were found to be statistically indistinguishable at either field strength (P = 0.07 at 1.5 T and P = 0.07 at 3.0 T). Conclusions: The preliminary data presented here suggest that the 3DLL sequence provides accurate TI values with sufficient in-plane resolution and allows full joint coverage in less than 10 minutes.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 12 条
[1]
Glycosaminoglycan in articular cartilage: In vivo assessment with delayed Gd(DTPA)(2-)-enhanced MR imaging [J].
Bashir, A ;
Gray, ML ;
Boutin, RD ;
Burstein, D .
RADIOLOGY, 1997, 205 (02) :551-558
[2]
FAST AND PRECISE T1 IMAGING USING A TOMROP SEQUENCE [J].
BRIX, G ;
SCHAD, LR ;
DEIMLING, M ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :351-356
[3]
MRI techniques in early stages of cartilage disease [J].
Burstein, D ;
Bashir, A ;
Gray, ML .
INVESTIGATIVE RADIOLOGY, 2000, 35 (10) :622-638
[4]
A fast 3D Look-Locker method for volumetric T1 mapping [J].
Henderson, E ;
McKinnon, G ;
Lee, TY ;
Rutt, BK .
MAGNETIC RESONANCE IMAGING, 1999, 17 (08) :1163-1171
[5]
A NEW METHOD OF COMPUTING SPIN-LATTICE RELAXATION MAPS IN MAGNETIC-RESONANCE IMAGING USING FAST SCANNING PROTOCOLS [J].
HINSON, WH ;
SOBOL, WT .
MEDICAL PHYSICS, 1988, 15 (04) :551-561
[6]
PRACTICAL IMPLEMENTATION AND OPTIMIZATION OF ONE-SHOT T1 IMAGING [J].
KAY, I ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :414-424
[7]
AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS [J].
MARQUARDT, DW .
JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02) :431-441
[8]
MCKENZIE CA, 2005, P INT SOC MAGN RES M, P472
[9]
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[10]
2-S