Absolute measurements of local chromophore concentrations using pulsed photoacoustic spectroscopy

被引:5
作者
Laufer, J. [1 ]
Elwell, C.
Delpy, D.
Beard, P.
机构
[1] UCL, Dept Med Phys & Bioengn, Malet Pl Engn Bldg, London WC1E 6BT, England
[2] Malet Palace Engn Bldg, London WC1E 6BT, England
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2006 | 2006年 / 6086卷
关键词
D O I
10.1117/12.657372
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Photoacoustic spectroscopy has the potential to make non-invasive, spatially resolved measurements of absolute chromophore concentrations. This has a wide range of possible applications, for example the mapping of endogenous chromophores such as oxy- (HbO(2)) and deoxyhaemoglobin (HHb) or externally administered contrast agents designed to target specific tissues or molecular processes. In this study we used near-infrared photoacoustic spectroscopy to determine the absolute concentrations of HbO(2) and HHb in a tissue phantom. The phantom consisted of three blood filled capillaries (O460microns) suspended at depths between 3mm and 9mm in a 2.5% Intralipid solution which also contained 2% blood in order to simulate the background optical attenuation in biological tissue. The blood oxygen saturation (SO2) of the blood circulating in the capillaries was varied using a membrane oxygenator. At each SO2 level, nanosecond pulses emitted by an OPO laser system that was tuneable over the wavelength range from 740nm to 1040nm illuminated the phantom. The generated photoacoustic waves were recorded using a single Fabry-Perot ultrasound detector and used to obtain a depth profile of the location of the tubes. The amplitudes of the part of the photoacoustic signal that corresponded to the capillaries and the surface of the Intralipid/blood mixture were plotted as a function of wavelength. The output of a diffusion theory based model of the wavelength dependence of the photoacoustic signal amplitude was then fitted to these spectra. This enabled the quantitative determination of absolute HbO(2) and HHb concentrations in the capillaries and the Intralipid/blood mixture from which the total haemoglobin concentrations and blood SO2 were calculated. Based on these measurements, the smallest chromophore concentrations that can be detected in biological tissue were estimated.
引用
收藏
页数:8
相关论文
共 11 条
[1]   Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection [J].
Beard, PC ;
Pérennès, F ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) :1575-1582
[2]  
Cope M., 1991, APPL NEAR INFRARED S
[3]   Two-dimensional quantitative photoacoustic image reconstruction of absorption distributions in scattering media by use of a simple iterative method [J].
Cox, BT ;
Arridge, SR ;
Köstli, KP ;
Beard, PC .
APPLIED OPTICS, 2006, 45 (08) :1866-1875
[4]   OPTICAL-CONSTANTS OF WATER IN 200-NM TO 200-MUM WAVELENGTH REGION [J].
HALE, GM ;
QUERRY, MR .
APPLIED OPTICS, 1973, 12 (03) :555-563
[5]   Thermoacoustic in vivo determination of blood oxygenation [J].
Kiser, WL ;
Kruger, RA ;
Reinecke, D ;
Kruger, G ;
Miller, KD .
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING, 2004, 5320 :1-7
[6]   Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response [J].
Köstli, KP ;
Beard, PC .
APPLIED OPTICS, 2003, 42 (10) :1899-1908
[7]   In vitro measurements of absolute blood oxygen saturation using pulsed near-infrared photoacoustic spectroscopy:: accuracy and resolution [J].
Laufer, J ;
Elwell, C ;
Delpy, D ;
Beard, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (18) :4409-4428
[8]  
Laufer JG, 2006, ADV EXP MED BIOL, V578, P155
[9]   Determination of visible near-IR absorption coefficients of mammalian fat using time- and spatially resolved diffuse reflectance and transmission spectroscopy [J].
van Veen, RLP ;
Sterenborg, HJCM ;
Pifferi, A ;
Torricelli, A ;
Chikoidze, E ;
Cubeddu, R .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (05)
[10]   LIGHT-SCATTERING IN INTRALIPID-10-PERCENT IN THE WAVELENGTH RANGE OF 400-1100 NM [J].
VANSTAVEREN, HJ ;
MOES, CJM ;
VANMARLE, J ;
PRAHL, SA ;
VANGEMERT, MJC .
APPLIED OPTICS, 1991, 30 (31) :4507-4514