Two-stage air-source heat pump for residential heating and cooling applications in northern US climates

被引:267
作者
Bertsch, Stefan S. [1 ]
Groll, Eckhard A. [1 ]
机构
[1] Purdue Univ, Sch Mech Engn, Ray W Herrick Labs, W Lafayette, IN 47907 USA
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2008年 / 31卷 / 07期
关键词
Heat pump; Air-source; Compression system; Two-stage system; R410A; Design; Experiment;
D O I
10.1016/j.ijrefrig.2008.01.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-source heat pumps for residential heating are more widely used than geothermal heat pumps mainly due to their lower installation costs. Major disadvantages of air-source heat pumps are the decrease of heat output and coefficient of performance (COP), and increase in discharge temperature, towards low outdoor temperatures. In this paper an air-source two-stage heat pump using R410A as the refrigerant was simulated, designed, constructed, and tested at ambient temperatures as low as -30 degrees C and supply temperatures of up to 50 degrees C in air and water heating mode. In addition, the system is able to provide sufficient air conditioning in cooling mode (approximately 5G-60% of the design heat transfer rate in heating mode). A short summary of an extended literature review is shown as well as a theoretical screening study of the three most promising cycles. Furthermore, the design and test results of a breadboard system and a comparison with commercially available heat pumps are presented. Second law efficiencies of up to 45% could be achieved, resulting in a coefficient of performance (COP) of 2.1 at -30 degrees C ambient temperature. (C) 2008 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1282 / 1292
页数:11
相关论文
共 16 条
[1]  
[Anonymous], 7 INT EN AG HEAT PUM
[2]  
[Anonymous], 1999, 5401999 ANSIARI
[3]  
*ARI, 2003, 2102402003 ARI
[4]  
ASHRAE, 2000, ASHRAE HDB HVAC SYST
[5]  
Bertsch S, 2005, 8 INT EN AG HEAT PUM
[6]  
BERTSCH SS, 2005, THESIS PURDUE U W LA
[7]  
DABIRI AE, 1981, ASHRAE T, V87, P771
[8]  
INCROPERA FP, 2002, FUNDAMENTALS HEAT MA, pCH11
[9]   Optimization of matrix heat exchanger geometry [J].
Kumar, KP ;
Venkatarathnam, G .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2000, 122 (03) :579-586
[10]  
LEROY JT, 1997, RP859 ASHRAE PURD U