Wavelet transform-based QRS complex detector

被引:268
作者
Kadambe, S [1 ]
Murray, R
Boudreaux-Bartels, GF
机构
[1] HRL Labs LLC, Informat Sci Lab, Malibu, CA 90265 USA
[2] Univ Rhode Isl, Dept Elect Engn, Kingston, RI 02881 USA
关键词
American Heart Association (AHA) database; dyadic wavelet transform (DyWT) and its properties; performance comparison; QRS detector; robust detector;
D O I
10.1109/10.771194
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we describe a QRS complex detector based on the dyadic wavelet transform (D-g WT) which is robust to time-varying QRS complex morphology and to noise. We design a spline wavelet that is suitable for QRS detection. The scales of this wavelet are chosen based on the spectral characteristics of the electrocardiogram (ECG) signal. We illustrate the performance of the D-y WT-based QRS detector by considering problematic ECG signals from the American Heart Association (AHA) data base. Seventy hours of data was considered. We also compare the performance of D-y WT-based QRS detector with detectors based on Okada, Hamilton-Tompkins, and multiplication of the backward difference algorithms. From the comparison, results we observed that although no one algorithm exhibited superior performance in all situations, the D-y WT-based detector compared well with the standard techniques. For multiform premature ventricular contractions, bigeminy, and couplets tapes, the D-y WT-based detector exhibited excellent performance.
引用
收藏
页码:838 / 848
页数:11
相关论文
共 28 条
[1]  
[Anonymous], 1988, STOCHASTIC PROCESSES, DOI 10.1007/978-94-009-2893-0_7
[2]  
ARMSTRONG M, 1985, ELECTROCARDIOGRAMS
[3]   Wavelet packet-based compression of single lead ECG [J].
Bradie, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (05) :493-501
[4]   A COMPARISON OF THE NOISE SENSITIVITY OF 9 QRS DETECTION ALGORITHMS [J].
FRIESEN, GM ;
JANNETT, TC ;
JADALLAH, MA ;
YATES, SL ;
QUINT, SR ;
NAGLE, HT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :85-98
[5]   QUANTITATIVE INVESTIGATION OF QRS DETECTION RULES USING THE MIT/BIH ARRHYTHMIA DATABASE [J].
HAMILTON, PS ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) :1157-1165
[6]  
HLAWATSCH F, 1992, IEEE SIGNAL PROC APR, P21
[7]   APPLICATION OF THE WAVELET TRANSFORM FOR PITCH DETECTION OF SPEECH SIGNALS [J].
KADAMBE, S ;
BOUDREAUXBARTELS, GF .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1992, 38 (02) :917-924
[8]  
KADAMBE S, 1992, P 26 AS C SIGN SYST, P130
[9]  
LI C, 1993, P 15 ANN INT C IEEE, P330
[10]   DETECTION OF ECG CHARACTERISTIC POINTS USING WAVELET TRANSFORMS [J].
LI, CW ;
ZHENG, CX ;
TAI, CF .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (01) :21-28