Two-wavelength MAD phasing:: in search of the optimal choice of wavelengths

被引:22
作者
González, A
Pédelacq, JD
Solà, M
Gomis-Rüth, FX
Coll, M
Samama, JP
Benini, S
机构
[1] European Mol Biol Lab, Hamburg Outstn, D-22603 Hamburg, Germany
[2] CNRS, Inst Pharmacol & Biol Struct, Grp Cristallog Biol, F-31077 Toulouse, France
[3] CSIC, Ctr Invest & Desenvolupament, ES-08034 Barcelona, Spain
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 1999年 / 55卷
关键词
D O I
10.1107/S0907444999006745
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The multiwavelength anomalous dispersion (MAD) method is increasingly being used to determine protein crystal structures. In theory, data collection at two wavelengths is sufficient for the determination of MAD phases, but three or even more wavelengths are used most often. In this paper, the results of the phasing procedure using only two wavelengths for proteins containing different types of anomalous scatterers are analyzed. In these cases, it is shown that this approach leads to interpretable maps, similar in quality to those obtained with data collected at three wavelengths, provided that the wavelengths are chosen so as to give a large contrast in the real part of the anomalous scattering factor f. The consequences for a rational MAD data-collection strategy are discussed.
引用
收藏
页码:1449 / 1458
页数:10
相关论文
共 37 条
  • [1] THE CCP4 SUITE - PROGRAMS FOR PROTEIN CRYSTALLOGRAPHY
    BAILEY, S
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1994, 50 : 760 - 763
  • [2] Benini S, 1997, PROTEINS, V28, P580, DOI 10.1002/(SICI)1097-0134(199708)28:4<580::AID-PROT11>3.0.CO
  • [3] 2-C
  • [4] BIOU V, 1997, P CCP4 STUD WEEK REC, P97
  • [5] THE TREATMENT OF ERRORS IN THE ISOMORPHOUS REPLACEMENT METHOD
    BLOW, DM
    CRICK, FHC
    [J]. ACTA CRYSTALLOGRAPHICA, 1959, 12 (10): : 794 - 802
  • [6] A SUITE OF PROGRAMS FOR CALCULATING X-RAY ABSORPTION, REFLECTION, AND DIFFRACTION PERFORMANCE FOR A VARIETY OF MATERIALS AT ARBITRARY WAVELENGTHS
    BRENNAN, S
    COWAN, PL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) : 850 - 853
  • [7] WHITE LINES IN X-RAY ABSORPTION
    BROWN, M
    PEIERLS, RE
    STERN, EA
    [J]. PHYSICAL REVIEW B, 1977, 15 (02): : 738 - 744
  • [8] Data collection strategy
    Dauter, Z
    [J]. MACROMOLECULAR CRYSTALLOGRAPHY, PT A, 1997, 276 : 326 - 344
  • [9] SR INSTRUMENTATION FOR OPTIMIZED ANOMALOUS SCATTERING AND HIGH-RESOLUTION STRUCTURE STUDIES OF PROTEINS AND NUCLEIC-ACIDS
    DEACON, A
    HABASH, J
    HARROP, SJ
    HELLIWELL, JR
    HUNTER, WN
    LEONARD, GA
    PETERSON, M
    HADENER, A
    KALB, AJ
    ALLINSON, NM
    CASTELLI, C
    MOON, K
    MCSWEENEY, S
    GONZALEZ, A
    THOMPSON, AW
    EALICK, S
    SZEBENYI, DM
    WALTER, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) : 1287 - 1292
  • [10] DELAFORTELLE E, 1997, P CCP4 STUD WEEK REC, P25