Diamond beam-position monitor for undulator radiation and tests at the Tristan super light facility

被引:22
作者
Sakae, H
Aoyagi, H
Oura, M
Kimura, H
Ohata, T
Shiwaku, H
Yamamoto, S
Sugiyama, H
Tanabe, K
Kobashi, K
Kitamura, H
机构
[1] ISHIKAWAJIMA HARIMA HEAVY IND CO LTD,ISOGO KU,YOKOHAMA,KANAGAWA 235,JAPAN
[2] JAPAN SYNCHROTRON RADIAT RES INST,KAMIGORI,HYOGO 67812,JAPAN
[3] NATL LAB HIGH ENERGY PHYS,PHOTON FACTORY,TSUKUBA,IBARAKI 305,JAPAN
[4] SUMITOMO ELECT IND LTD,ITAMI,HYOGO 664,JAPAN
[5] KOBE STEEL LTD,NISHI KU,KOBE,HYOGO 65122,JAPAN
关键词
beam-position monitors; diamond; photoconductive mode; undulator radiation;
D O I
10.1107/S090904959700561X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A photon beam-position monitor using a diamond foil as a position-sensitive device has been developed for use on insertion-device beamlines of third-generation synchrotron radiation facilities such as SPring-8, and was tested on the undulator beamline of the Tristan Super Light Facility at KEK. The beam test results show that the diamond monitor can be operated in a photoconductive mode like a semiconductor detector. It has a linear working range of about fl mm and a position sensitivity of less than 3 mu m. The stability of the monitor was confirmed by continuous operation under low photon beam intensity conditions.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 10 条
[1]  
ANDO M, 1995, J PHYS SOC JPN, V50, P15
[2]   DEVELOPMENT OF DIAMOND RADIATION DETECTORS FOR SSC AND LHC [J].
FRANKLIN, M ;
FRY, A ;
GAN, KK ;
HAN, S ;
KAGAN, H ;
KANDA, S ;
KANIA, D ;
KASS, R ;
KIM, SK ;
MALCHOW, R ;
MORROW, F ;
OLSEN, S ;
PALMER, WF ;
PAN, LS ;
SANNES, F ;
SCHNETZER, S ;
STONE, R ;
SUGIMOTO, Y ;
THOMSON, GB ;
WHITE, C ;
ZHAO, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3) :39-42
[3]  
KITAMURA H, 1994, SPECTRA SYNCHROTON R
[4]  
Knoll G. F., 1989, RAD DETECTION MEASUR
[5]  
LOYER F, 1993, P DIPAC 93 MONTR
[6]  
*NAT LAB HIGH EN P, 1995, 12 NAT LAB HIGH EN P
[7]  
*NAT LAB HIGH EN P, 1995, 11 NAT LAB HIGH EN P
[8]  
*PHOT FACT, 1994, 11 PHOT FACT NAT LAB
[9]   SUPERBRILLIANT X-RAY UNDULATOR FOR THE TRISTAN SUPER LIGHT FACILITY [J].
YAMAMOTO, S ;
SHIOYA, T ;
KITAMURA, H ;
TSUCHIYA, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1996-1998
[10]   A WIRE SCANNING TYPE POSITION MONITOR FOR AN UNDULATOR RADIATION [J].
ZHANG, XW ;
SUGIYAMA, H ;
ANDO, M ;
XIA, SJ ;
SHIWAKU, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1990-1992