Validity of wearable actimeter computation of total energy expenditure during walking in post-stroke individuals

被引:12
作者
Compagnat, M. [1 ,2 ]
Mandigout, S. [1 ]
Batcho, C. S. [3 ,4 ]
Vuillerme, N. [5 ,6 ]
Salle, J. Y. [1 ,2 ]
David, R. [2 ]
Daviet, J. C. [1 ,2 ]
机构
[1] Univ Limoges, IFRH, EA6310, HAVAE,Handicap,Aging,Auton,Environm, F-87042 Limoges, France
[2] Univ Hosp Ctr Limoges, Dept Phys Med & Rehabil, 2 Ave Martin Luther King, F-87042 Limoges, France
[3] Ctr Integre Univ Sante & Serv Sociaux Capitale Na, Ctr Interdisciplinary Res Rehabil & Social Integr, Quebec City, PQ, Canada
[4] Univ Laval, Fac Med, Dept Rehabil, Quebec City, PQ, Canada
[5] Univ Grenoble Alpes, AGEIS, F-38706 Grenoble, France
[6] Inst Univ France, F-75000 Paris, France
关键词
Energy cost; Walking; Energy expenditure; Calibration; Accelerometer; Algorithm; PHYSICAL-ACTIVITY; STROKE SURVIVORS; MEASURING STEPS; PEDOMETERS; RELIABILITY; ACCELEROMETER;
D O I
10.1016/j.rehab.2019.07.002
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Recent studies reported that wearable sensor devices show low validity for assessing the amount of energy expenditure in individuals after stroke. Objective: We aimed to evaluate the validity of energy expenditure calculation based on the product of energy cost and walked distance estimated by wearable devices in individuals after hemispheric stroke. Methods: We recruited individuals with hemispheric stroke sequelae who were able to walk without human assistance. The participants wore a tri-axial accelerometer (Actigraph GT3x) and a pedometer (ONStep 400) on the unaffected hip in addition to a respiratory gas exchange analyzer (METAMAX 3B) during 6 min of walking at their self-selected walking speed and mode. The energy expenditure was calculated from the product of energy cost measured by the METAMAX 3B and the distance estimated by wearable devices. It was compared to the energy expenditure measured by the METAMAX 3B and the energy expenditure values recorded by the devices according to the manufacturer's algorithms. The validity was investigated by Bland-Altman analysis (mean bias [MB], root mean square error [RMSE], limits of agreement [95%LoA]), and Pearson correlation analysis (r). Results: We included 26 participants (mean [SD] age 64.6 [14.8] years). With the pedometer, the energy expenditure calculated from the product of energy cost and walked distance showed high accuracy and agreement with METAMAX 3B values (MB = -1.6 kcal; RMSE = 4.1 kcal; 95%LoA = -9.9; 6.6 kcal; r = 0.87, P < 0.01) but low accuracy and agreement with Actigraph GT3x values (MB = 15.7 kcal; RMSE = 8.7 kcal; 95%LoA = -1.3; 32.6 kcal; r = 0.44, P = 0.02) because of poorer estimation of walked distance. With the pedometer, this new method of calculation strongly increased the validity parameter values for estimating energy expenditure as compared with the manufacturer's algorithm. Conclusions: This new method based on the energy cost and distance estimated by wearable devices provided better energy expenditure estimates for the pedometer than did the manufacturer's algorithm. The validity of this method depended on the accuracy of the sensor to measure the distance walked by an individual after stroke. (C) 2019 Published by Elsevier Masson SAS.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 36 条
[1]   2011 Compendium of Physical Activities: A Second Update of Codes and MET Values [J].
Ainsworth, Barbara E. ;
Haskell, William L. ;
Herrmann, Stephen D. ;
Meckes, Nathanael ;
Bassett, David R., Jr. ;
Tudor-Locke, Catrine ;
Greer, Jennifer L. ;
Vezina, Jesse ;
Whitt-Glover, Melicia C. ;
Leon, Arthur S. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (08) :1575-1581
[2]   Wearable Systems for Monitoring Mobility-Related Activities in Chronic Disease: A Systematic Review [J].
Allet, Lara ;
Knols, Ruud H. ;
Shirato, Kei ;
de Bruin, Eling D. .
SENSORS, 2010, 10 (10) :9026-9052
[3]   Variability in spatiotemporal step characteristics and its relationship to walking performance post-stroke [J].
Balasubramanian, Chitralakshmi K. ;
Neptune, Richard R. ;
Kautz, Steven A. .
GAIT & POSTURE, 2009, 29 (03) :408-414
[4]   Measuring moderate-intensity walking in older adults using the ActiGraph accelerometer [J].
Barnett, Anthony ;
van den Hoek, Daniel ;
Barnett, David ;
Cerin, Ester .
BMC GERIATRICS, 2016, 16
[5]   Use of pedometers and accelerometers in clinical populations: validity and reliability issues [J].
Bassett, David, Jr. ;
John, Dinesh .
PHYSICAL THERAPY REVIEWS, 2010, 15 (03) :135-142
[6]   Accelerometer-based Physical Activity: Total Volume per Day and Standardized Measures [J].
Bassett, David R. ;
Troiano, Richard P. ;
Mcclain, James J. ;
Wolff, Dana L. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (04) :833-838
[7]   Calibration and Validation of Wearable Monitors [J].
Bassett, David R., Jr. ;
Rowlands, Alex ;
Trost, Stewart G. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 :S32-S38
[8]   Physical Activity and Exercise Recommendations for Stroke Survivors A Statement for Healthcare Professionals From the American Heart Association/American Stroke Association [J].
Billinger, Sandra A. ;
Arena, Ross ;
Bernhardt, Julie ;
Eng, Janice J. ;
Franklin, Barry A. ;
Johnson, Cheryl Mortag ;
MacKay-Lyons, Marilyn ;
Macko, Richard F. ;
Mead, Gillian E. ;
Roth, Elliot J. ;
Shaughnessy, Marianne ;
Tang, Ada .
STROKE, 2014, 45 (08) :2532-2553
[9]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[10]  
Brun V, 2000, Ann Readapt Med Phys, V43, P14, DOI [10.1016/S0168-6054(00)87937-4, DOI 10.1016/S0168-6054(00)87937-4]