Immobilization of glucose oxidase on thin-film gold electrodes produced by magnetron sputtering and their application in an electrochemical biosensor

被引:12
作者
Gil, MH [1 ]
Sardinha, JP
Vieira, MT
Vivan, M
Costa, D
Rodrigues, C
Matysik, FM
Brett, AMO
机构
[1] Univ Coimbra, Dept Engn Quim, P-3000 Coimbra, Portugal
[2] Univ Coimbra, Dept Engn Mecan, P-3000 Coimbra, Portugal
[3] Univ Coimbra, Dept Quim, P-3000 Coimbra, Portugal
[4] Univ Coimbra Hosp, P-3000 Coimbra, Portugal
[5] Univ Leipzig, Inst Analyt Chem, D-04103 Leipzig, Germany
关键词
cathodic sputtering; electrochemical biosensor; glucose; thin-layer gold-sputtered film electrode;
D O I
10.1023/A:1008910304393
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electrochemical biosensor is described consisting of a thin-layer gold film electrode prepared by cathodic sputtering using a poly(vinyl chloride) sheet as substrate, with voltammetric behaviour comparable to that of conventional polycrystalline gold electrodes, coated with the hydrolysed copolymer hydroxyethyl methacrylate-co-methyl methacrylate onto which glucose oxidase was immobilized. The mechanical properties of the plastic foil substrate permit easy construction of circular-shaped electrodes which were employed as working electrodes for batch injection analysis. The electrochemical biosensor fabrication is inexpensive and can be used as disposable enzyme sensor for the detection of hydrogen peroxide. The biosensor was tested for the determination of glucose in serum and a good correlation was obtained with the measurement using the electrochemical and the spectrophotometric methods.
引用
收藏
页码:595 / 599
页数:5
相关论文
共 14 条
[1]   Thin-film gold electrodes produced by magnetron sputtering. Voltammetric characteristics and application in batch injection analysis with amperometric detection [J].
Brett, AMO ;
Matysik, FM ;
Vieira, MT .
ELECTROANALYSIS, 1997, 9 (03) :209-212
[2]  
BRETT AMO, 1993, BIOELECTROCH BIOENER, V31, P311
[3]   Anodic stripping voltammetry of trace metals by batch injection analysis [J].
Brett, CMA ;
Brett, AMO ;
Tugulea, L .
ANALYTICA CHIMICA ACTA, 1996, 322 (03) :151-157
[4]   Nafion-coated mercury thin film electrodes for batch-injection analysis with anodic stripping voltammetry [J].
Brett, CMA ;
Brett, AMO ;
Matysik, FM ;
Matysik, S ;
Kumbhat, S .
TALANTA, 1996, 43 (11) :2015-2022
[5]  
Cass A. E. G., 1990, BIOSENSORS PRACTICAL
[6]  
GIL MH, 1996, POLYM MAT ENCY, V5, P3190
[7]  
Henry C, 1998, ANAL CHEM, V70, p594A
[8]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205
[9]   Trends in electrochemical biosensors [J].
Magner, E .
ANALYST, 1998, 123 (10) :1967-1970
[10]  
NEWMAN JD, 1994, CHEM IND, V7, P374