Time dependence of defibrillator benefit after coronary revascularization in the multicenter automatic defibrillator implantation trial (MADIT)-II

被引:82
作者
Goldenberg, I
Moss, AJ
McNitt, S
Zareba, W
Hafl, WJ
Andrews, ML
Wilber, DJ
Klein, HU
机构
[1] Univ Rochester, Med Ctr, Dept Med, Cardiol Unit,Heart Res Follow Up Program, Rochester, NY 14642 USA
[2] Univ Rochester, Med Ctr, Dept Biostat & Computat Biol, Rochester, NY 14642 USA
[3] Loyola Univ, Cardiovasc Inst, Ctr Med, Maywood, IL 60153 USA
[4] Univ Hosp, Div Cardiol, Magdeburg, Germany
关键词
D O I
10.1016/j.jacc.2005.12.048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The study was designed to assess the effect of elapsed time from coronary revascularization (CR) on the benefit of the implantable cardioverter-defibrillator (ICD) and the risk of sudden cardiac death (SCD) in patients with ischemic left ventricular dysfunction. BACKGROUND The ICD improves survival in appropriately selected high-risk cardiac patients by 30% to 54%. However, in the Coronary Artery Bypass Graft (CABG)-Patch trial no evidence of improved survival was shown among a similar population of patients in whom an ICD was implanted prophylactically at the time of elective CABG. METHODS The outcome by time from CR was analyzed in 951 patients in whom a revascularization procedure was performed before enrollment in the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II. RESULTS The adjusted hazard ratio (HR) of ICD versus conventional therapy was 0.64 (p = 0.01) among patients enrolled more than six months after CR, whereas 110 survival benefit with ICD therapy was shown among patients enrolled six months or earlier after CR (HR = 1.19; p = 0.76). In the conventional therapy group, the risk of cardiac death increased significantly with increasing time from CR (p for trend = 0.009), corresponding mainly to a six-fold increase in the risk of SCD among patients enrolled more than six months after CR. CONCLUSIONS In patients with ischemic left ventricular dysfunction, the efficacy of ICD therapy after CR is time dependent, with a significant life-saving benefit in patients receiving device implantation more than six months after CR. The lack of ICD benefit when implanted early after CR may be related to a relatively low risk of SCD during this time period.
引用
收藏
页码:1811 / 1817
页数:7
相关论文
共 16 条
[1]  
[Anonymous], 1982, Lancet, V2, P1173
[2]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[3]   Mechanisms of death in the CABG Patch trial - A randomized trial of implantable cardiac defibrillator prophylaxis in patients at high risk of death after coronary artery bypass graft surgery [J].
Bigger, JT ;
Whang, W ;
Rottman, JN ;
Kleiger, RE ;
Gottlieb, CD ;
Namerow, PB ;
Steinman, RC ;
Estes, NAM .
CIRCULATION, 1999, 99 (11) :1416-1421
[4]   Prophylactic use of implanted cardiac defibrillators in patients at high risk for ventricular arrhythmias after coronary-artery bypass graft surgery [J].
Bigger, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (22) :1569-1575
[5]   A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[6]  
Eagle Kim A, 2004, Circulation, V110, P1168, DOI 10.1161/01.CIR.0000138790.14877.7D
[7]   Analysis of mortality events in the multicenter automatic defibriflator implantation trial (NLADIT-II) [J].
Greenberg, H ;
Case, RB ;
Moss, AJ ;
Brown, MW ;
Carroll, ER ;
Andrews, ML .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (08) :1459-1465
[8]   THE EFFECT OF MEDICAL AND SURGICAL-TREATMENT ON SUBSEQUENT SUDDEN CARDIAC DEATH IN PATIENTS WITH CORONARY-ARTERY DISEASE - A REPORT FROM THE CORONARY-ARTERY SURGERY STUDY [J].
HOLMES, DR ;
DAVIS, KB ;
MOCK, MB ;
FISHER, LD ;
GERSH, BJ ;
KILLIP, T ;
PETTINGER, M .
CIRCULATION, 1986, 73 (06) :1254-1263
[9]  
McAnulty J, 1997, NEW ENGL J MED, V337, P1576
[10]   Temporal aspects of improved survival with the implanted defibrillator (MADIT-II) [J].
Moss, AJ ;
Vyas, A ;
Greenberg, H ;
Case, RB ;
Zareba, W ;
Hall, WJ ;
Brown, MW ;
McNitt, SA ;
Andrews, ML .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (03) :312-315