Color flow mapping

被引:58
作者
Ferrara, K [1 ]
DeAngelis, G [1 ]
机构
[1] UNIV VIRGINIA, DEPT RADIOL, CHARLOTTESVILLE, VA 22908 USA
关键词
Doppler; color flow mapping; contrast agents; second harmonic imaging; wall filters; wideband estimation techniques; narrowband estimation techniques; flow discrimination; aliasing; artifacts;
D O I
10.1016/S0301-5629(96)00216-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Color flow mapping systems have become widely used in the short time since their development. These systems overlay a pseudo-color velocity map upon the gray-scale two-dimensional image. Between 4 and 16 pulses are directed to each line-of-sight, and this requirement reduces the frame rate in comparison with the gray-scale image. Other limitations of color flow mapping include its ability to estimate only the velocity toward or away from the transducer and an increase in the variance in comparison with spectral Doppler. Potential artifacts include aliased velocities and the detection of how in hypoechoic or hyperechoic nonvascular structures. Clinical applications include cardiology, studies of the abdominal and peripheral vasculature, evaluation of organ perfusion and the differentiation of tumors. Most current systems use narrowband estimators that examine a fixed sample volume and detect a change in phase between two pulses. Wideband estimators that can track red blood cells in two or three dimensions are under evaluation. Narrowband estimators, including the autocorrelator, the short Fourier transform and second order autoregressive filters, are compared with wideband estimators including cross-correlation, sum-absolute-difference and the wideband maximum likelihood estimator. Because the intensity of blood echoes is far smaller than echoes from surrounding tissue, high pass filters have been developed that can reject the larger signal from tissue using the return from a small number of pulses. Other areas of research include strategies for how estimation with contrast agents, three-dimensional color flow mapping and power Doppler flow mapping. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:321 / 345
页数:25
相关论文
共 78 条
[1]  
AHN YB, 1991, IEEE T ULTRASON FERR, V38, P172, DOI 10.1109/58.79600
[2]  
ALLEN BT, 1992, J CARDIOVASC SURG, V33, P440
[3]  
American Institute of Ultrasound in Medicine (AIUM), 1993, PERF CRIT MEAS DOPPL
[4]   THEORETICAL-STUDY OF THE SCATTERING OF ULTRASOUND FROM BLOOD [J].
ANGELSEN, BAJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (02) :61-67
[5]  
[Anonymous], DOPPLER ULTRASOUND C
[6]  
[Anonymous], 1971, DETECTION ESTIMATION
[7]   RANDOM NOISE IN ULTRASONIC ECHOES DIFFRACTED BY BLOOD [J].
ATKINSON, P ;
BERRY, MV .
JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 1974, 7 (11) :1293-1302
[8]   ULTRASONIC RANDOM-SIGNAL FLOW MEASUREMENT SYSTEM [J].
BENDICK, PJ ;
NEWHOUSE, VL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1974, 56 (03) :860-865
[9]  
BERTRAM C D, 1979, Ultrasound in Medicine and Biology, V5, P61, DOI 10.1016/0301-5629(79)90128-5
[10]   A REAL-TIME SYSTEM FOR QUANTIFYING AND DISPLAYING 2-DIMENSIONAL VELOCITIES USING ULTRASOUND [J].
BOHS, LN ;
FRIEMEL, BH ;
MCDERMOTT, BA ;
TRAHEY, GE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :751-761