Standardization of immunoassays for measurement of myoglobin in serum. Phase 1: Evaluation of candidate secondary reference materials

被引:17
作者
Panteghini, M [1 ]
Linsinger, T
Wu, AHB
Dati, F
Apple, FS
Christenson, RH
Mair, J
Schimmel, H
机构
[1] Azienda Osped Spedali Civili, Lab Anal Chim Clin 1, I-25125 Brescia, Italy
[2] Inst Ref Mat & Measurements, Geel, Belgium
[3] Hartford Hosp, Dept Pathol & Lab Med, Hartford, CT USA
[4] IVD Consulting, Marburg, Germany
[5] Hennepin Cty Med Ctr, Dept Lab Med & Pathol, Minneapolis, MN USA
[6] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
[7] Univ Maryland, Med Sch Med, Dept Pathol, Baltimore, MD 21201 USA
[8] Univ Innsbruck, Sch Med, Div Cardiol, Dept Internal Med, Innsbruck, Austria
关键词
myoglobin; standardization; commutability; reference materials;
D O I
10.1016/j.cccn.2003.10.030
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Myoglobin is a low-molecular weight protein present in the cytosol of striated muscles. Its concentrations in serum can be measured by immunoassays and are used as an early indicator of myocardial necrosis. Since variability among commercial myoglobin assays exists, standardization of myoglobin assays is needed. Methods: An international collaborative study was organized with the involvement of seven companies using 12 different automated platforms for measuring myoglobin. Five candidate secondary, i.e., matrixed, reference materials were assayed in relation to linearity, imprecision, recovery rate and commutability to demonstrate a possible identity between the materials and the usual routine serum samples. Results: One Iyophilized candidate material (human heart myoglobin in human serum) was selected as the most suitable secondary reference material, based on the criteria examined. Used as a calibrator a posteriori, the bias between the various myoglobin assays for a frozen human serum pool was reduced from 32% to 13%. Conclusion: This study provides the basis for the selection of an internationally recognized secondary reference material. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 21 条
[1]  
Christenson RH, 2001, CLIN CHEM, V47, P431
[2]  
Christenson RH, 1999, CLIN CHEM, V45, P1414
[3]  
*COLL AM PATH, 2003, CARD MARK SURV
[4]  
Dati F, 1999, SCAND J CLIN LAB INV, V59, P113
[5]  
DATI F, 2002, CLIN CHEM LAB MED, V40, pS311
[6]  
Fesmire FM, 2000, ANN EMERG MED, V35, P521, DOI 10.1067/mem.2000.106387
[7]  
Jesse RL, 2003, PATHOL LAB MED, P245
[8]   Extensive troponin I and T modification detected in serum from patients with acute myocardial infarction [J].
Labugger, R ;
Organ, L ;
Collier, C ;
Atar, D ;
Van Eyk, JE .
CIRCULATION, 2000, 102 (11) :1221-1226
[9]   Determination of myoglobin: comparative evaluation of the new automated VIDASR assay with two other immunoassays [J].
Le Moigne, F ;
Beauvieux, MC ;
Derache, P ;
Darmon, YM .
CLINICAL BIOCHEMISTRY, 2002, 35 (04) :255-262
[10]   Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes [J].
Miller, WG .
CLINICA CHIMICA ACTA, 2003, 327 (1-2) :25-37