Microscopic computed tomography imaging of the cerebral circulation in mice: Feasibility and pitfalls

被引:13
作者
Abruzzo, T. [1 ]
Tumialan, L. [2 ]
Chaalala, C. [3 ]
Kim, S. [2 ]
Guldberg, R. E. [4 ,5 ]
Lin, A. [4 ,5 ]
Leach, J. [6 ]
Khoury, J. C. [7 ]
Morgan, A. E. [1 ]
Cawley, C. M., III [2 ]
机构
[1] Univ Cincinnati, Med Ctr, Div Intervent Neuroradiol, Dept Radiol,Neurosci Inst, Cincinnati, OH 45267 USA
[2] Emory Univ, Sch Med, Dept Neurosurg, Sect Cerebrovasc Surg, Atlanta, GA 30302 USA
[3] Univ Cincinnati, Med Ctr, Dept Neurosurg, Div Vasc Neurosurg, Cincinnati, OH 45267 USA
[4] Georgia Inst Technol, Sch Mech Engn, Atlanta, GA 30332 USA
[5] Georgia Inst Technol, Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
[6] Univ Cincinnati, Med Ctr, Dept Radiol, Div Diagnost Neuroradiol, Cincinnati, OH 45267 USA
[7] Univ Cincinnati, Med Ctr, Dept Environm Hlth, Div Epidemiol & Biostat, Cincinnati, OH 45267 USA
关键词
micro CT; cerebral arterial circulation; mice; murine; circle of willis;
D O I
10.1002/syn.20511
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study evaluates the utility and practical limitations of microcomputerized X-ray tomography (CT) as a research tool for examination of the cerebral circulation in mice. Six micro CT angiograms of the circle of Willis (COW) from six mice were obtained by scanning whole head and brain specimen perfused with a radio-opaque silicone contrast agent. Two-dimensional volume rendered images were postprocessed from three-dimensional image datasets using a partially automated high-throughput model that generated 10 surface projections for each specimen. The image processing model employed a straightforward global thresholding and computerized component labeling software algorithm. Postprocessed images were analyzed and results correlated with microdissection. Micro CT demonstration of COW vessels and their branch anatomy was assessed. 71% of COW vessels were completely demonstrated, 26% were partially demonstrated, and 3% were not demonstrated. All cases of nondemonstration and most cases of partial demonstration resulted from scan coverage or postprocessing clip error. Thresholding effect caused pseudostenosis of 8% of COW vessels and accounted for a minority of partial demonstration cases. No imaging artifacts were caused by contrast extravasation or ineffective contrast perfusion. Volume averaging caused minor angioarchitectural distortion of 58% of COW vessels. Ninety-five percent of COW >= 50 mu m and 52% of COW vessels < 50 mu m were correctly identified by micro CT. Micro CT of the murine COW using a high-throughput image processing model is feasible. Angioarchitectural distortion due to volume averaging and thresholding effect can occur and pathological findings should be confirmed.
引用
收藏
页码:557 / 565
页数:9
相关论文
共 13 条
[1]  
BAEDA CT, 2005, MOL IMAGING, V4, P110
[2]  
Bash S, 2005, AM J NEURORADIOL, V26, P1012
[3]  
Beckmann N, 2000, MAGNET RESON MED, V44, P252, DOI 10.1002/1522-2594(200008)44:2<252::AID-MRM12>3.0.CO
[4]  
2-G
[5]   Detection of intracranial aneurysms: Multi-detector row CT angiography compared with DSA [J].
Jayaraman, MV ;
Mayo-Smith, WW ;
Tung, GA ;
Haas, RA ;
Rogg, JM ;
Mehta, NR ;
Doberstein, CE .
RADIOLOGY, 2004, 230 (02) :510-518
[6]   Intracranial aneurysms: evaluation using CTA and MRA. Correlation with DSA and intraoperative findings [J].
Kouskouras, C ;
Charitanti, A ;
Giavroglou, C ;
Foroglou, N ;
Selviaridis, P ;
Kontopoulos, V ;
Dimitriadis, AS .
NEURORADIOLOGY, 2004, 46 (10) :842-850
[7]   CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms.: An experimental study [J].
Piotin, M ;
Gailloud, P ;
Bidaut, L ;
Mandai, S ;
Muster, M ;
Moret, J ;
Rüfenacht, DA .
NEURORADIOLOGY, 2003, 45 (06) :404-409
[8]  
Thali MJ, 2003, J FORENSIC SCI, V48, P386
[9]   Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography [J].
Tipper, G ;
U-King-Im, JM ;
Price, SJ ;
Trivedi, RA ;
Cross, JJ ;
Higgins, NJ ;
Farmer, R ;
Wat, J ;
Kirollos, R ;
Kirkpatrick, PJ ;
Antoun, NM ;
Gillard, JH .
CLINICAL RADIOLOGY, 2005, 60 (05) :565-572
[10]  
Villablanca JP, 2002, AM J NEURORADIOL, V23, P1187