Comparison of low- and medium-pressure ultraviolet lamps: Photoreactivation of Escherichia coli and total coliforms in secondary effluents of municipal wastewater treatment plants

被引:86
作者
Guo, Meiting [1 ]
Hu, Hongying [1 ]
Bolton, James R. [2 ]
El-Din, Mohamed Gamal [2 ]
机构
[1] Tsinghua Univ, Dept Environm Sci & Engn, Beijing 100084, Peoples R China
[2] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB T6G 2W2, Canada
关键词
Ultraviolet disinfection; Photoreactivation; Wastewater disinfection; Medium-pressure UV lamp; UV DISINFECTION; POTENTIAL REPAIR; DRINKING-WATER; BENCH-SCALE; INACTIVATION; RADIATION; EXPOSURE; LIGHT; TECHNOLOGIES; IRRADIATION;
D O I
10.1016/j.watres.2008.11.028
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
It has been reported that Medium-Pressure (MP) ultraviolet (UV) lamps have an advantage over low-pressure (LP) lamps for water disinfection in terms of the photoreactivation of pure cultured bacteria. However, few studies have investigated the behavior of microorganisms in wastewater. Hence, in this study, the degree of photoreactivation, after UV exposure using both LP and MP lamps, in municipal wastewater samples was examined under a variety of conditions. Pure cultured Escherichia coli was also used to provide a comparison with previous studies. E. coli was found to undergo photoreactivation after both LP and MP exposure. The Colony Forming Ability (CFA) ratios were 0.60 and 0.32, and the percentage of photoreactivation was 50% and 20%, respectively, for LP and MP lamps with a germicidal UV dose of 5 mJ/cm(2). However, the advantage of the MP lamp was diminished for larger UV doses, since no photoreactivation was detected when the UV dose was 15 mJ/cm(2) for either LP or MP lamps. The microorganisms present in wastewater showed similar results to those of E. coli, however, no significant difference was found between the use of either a LP or a MP lamp. Also, when a UV dose of 40 mJ/cm(2) was applied, the percentage photoreactivation was less than 1%, no matter which type of lamp was used. From this work, it is concluded that the selection of the type of UV lamp for wastewater treatment plants, as regards photo reactivation of total coliforms, is not critical as long as the applied germicidal UV dose is greater than 40 mJ/cm(2). (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:815 / 821
页数:7
相关论文
共 33 条
[1]   Assessment of DNA damage and repair in Mycobacterium terrae after exposure to UV irradiation [J].
Bohrerova, Z. ;
Linden, K. G. .
JOURNAL OF APPLIED MICROBIOLOGY, 2006, 101 (05) :995-1001
[2]   Standardization of methods for fluence (UV dose) determination in bench-scale UV experiments [J].
Bolton, JR ;
Linden, KG .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2003, 129 (03) :209-215
[3]   Wastewater disinfection with PAA and UV combined treatment: a pilot plant study [J].
Caretti, C ;
Lubello, C .
WATER RESEARCH, 2003, 37 (10) :2365-2371
[4]   Disinfecting behaviour of peracetic acid for municipal wastewater reuse [J].
Dell'Erba, A. ;
Falsanisi, D. ;
Liberti, L. ;
Notarnicola, M. ;
Santoro, D. .
DESALINATION, 2004, 168 :435-442
[5]   Sensor factor correction for collimated beam experiments using a medium pressure ultraviolet lamp [J].
Guo, Mei-Ting ;
Hu, Hong-Ying ;
Bolton, James R. .
JOURNAL OF ENVIRONMENTAL ENGINEERING AND SCIENCE, 2008, 7 (06) :677-679
[6]   Inactivation credit of UV radiation for viruses, bacteria and protozoan (oo)cysts in water: A review [J].
Hijnen, WAM ;
Beerendonk, EF ;
Medema, GJ .
WATER RESEARCH, 2006, 40 (01) :3-22
[7]  
Hoyer O., 1998, Water Supply, V16, P419
[8]   Effects of UV radiation on photolyase and implications with regards to photoreactivation following low- and medium-pressure UV disinfection [J].
Hu, Jiangyong ;
Quek, Puay Hoon .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (01) :327-328
[9]   Repair and regrowth of Escherichia coli after low- and medium-pressure ultraviolet disinfection [J].
Hu, JY ;
Chu, XN ;
Quek, PH ;
Feng, YY ;
Tan, XL .
Leading-Edge Technology 2005 - Water Treatment, 2005, 5 (05) :101-108
[10]   Particle effects on ultraviolet disinfection of coliform bacteria in recycled water [J].
Jolis, D ;
Lam, C ;
Pitt, P .
WATER ENVIRONMENT RESEARCH, 2001, 73 (02) :233-236