Segmentation of ultrasound B-mode images with intensity inhomogeneity correction

被引:144
作者
Xiao, GF [1 ]
Brady, M [1 ]
Noble, JA [1 ]
Zhang, YY [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Med Vis Lab, Oxford OX1 3PJ, England
关键词
contrast enhancement; intensity inhomogeneity; Markov random field; segmentation; tissue classification; ultrasound;
D O I
10.1109/42.981233
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Displayed ultrasound (US) B-mode images often exhibit tissue intensity inhomogeneities dominated by nonuniform beam attenuation within the body. This is a major problem for intensity-based, automatic segmentation of video-intensity images because conventional threshold-based or intensity-statistic-based approaches do not work well in the presence of such image distortions. Time gain compensation (TGC) is typically used in standard US machines in an attempt to overcome this. However this compensation method is position-dependent which means that different tissues in the same TGC time-range (or corresponding depth range) will be, incorrectly, compensated by the same amount. Compensation should really be tissue-type dependent but automating this step is difficult. The main contribution of this paper is to develop a method for simultaneous estimation of video-intensity inhomogeities and segmentation of US image tissue regions. The method uses a combination of the maximum a posteriori (MAP) and Markov random field (MRF) methods to estimate the US image distortion field assuming it follows a multiplicative model while at the same time labeling image regions based on the corrected intensity statistics. The MAP step is used to estimate the intensity model parameters while the MRF step provides a novel way of incorporating the distributions of image tissue classes as a spatial smoothness constraint. We explain how this multiplicative model can be related to the ultrasonic physics of image formation to justify our approach. Experiments are presented on synthetic images and a gelatin phantom to evaluate quantitatively the accuracy of the method. We also discuss qualitatively the application of the method to clinical breast and cardiac US images. Limitations of the method and potential clinical applications are outlined in the conclusion.
引用
收藏
页码:48 / 57
页数:10
相关论文
共 24 条
  • [1] [Anonymous], 1989, GENETIC ALGORITHM SE
  • [2] [Anonymous], MED IMAGING SYSTEMS
  • [3] Multiple resolution Bayesian segmentation of ultrasound images
    Ashton, EA
    Parker, KJ
    [J]. ULTRASONIC IMAGING, 1995, 17 (04) : 291 - 304
  • [4] BAMBER JC, 1986, ULTRASONICS, P41
  • [5] BESAG J, 1974, J ROY STAT SOC B MET, V36, P192
  • [6] BESAG J, 1986, J R STAT SOC B, V48, P259
  • [7] A multiparametric and multiresolution segmentation algorithm of 3-D ultrasonic data
    Boukerroui, D
    Basset, O
    Baskurt, A
    Gimenez, G
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) : 64 - 77
  • [8] BOUKERROUI D, 2002, IN PRESS PATTERN REC
  • [9] CASTELLINI G, 1988, J NUCL MED APPL SCI, V32, P213
  • [10] Adaptive speckle reduction filter for log-compressed B-scan images
    Dutt, V
    Greenleaf, JF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (06) : 802 - 813