Electron multiplying charge-coupled device camera based fluorescence correlation spectroscopy

被引:72
作者
Kannan, Balakrishnan
Har, Jia Yi
Liu, Ping
Maruyama, Ichiro
Ding, Jeak Ling
Wohland, Thorsten
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] Natl Univ Singapore, Dept Biol Sci, Singapore 117543, Singapore
[3] Singapore MIT Alliance, Singapore 117576, Singapore
[4] Genome Inst Singapore, Singapore 138672, Singapore
关键词
D O I
10.1021/ac0600959
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorescence correlation spectroscopy (FCS) setup is built with an electron multiplying charge-coupled device camera. Although the instrument has a limited time resolution of 4 ms, compared to 0.1-0.2 mu s for common instruments using avalanche photodiodes, it allows multiplexing of FCS measurements, has a software-adjustable pinhole after data collection, performs flow speed as well as flow direction measurements in microchannels and could be used to do spectral FCS. Measurements are performed on fluorescent dyes and polystyrene beads in high-viscosity media and on epidermal growth factor receptors in Chinese hamster ovary cells. Using real measurements on single spots, multiplexing of focal spots and detection elements are simulated and the results are discussed.
引用
收藏
页码:3444 / 3451
页数:8
相关论文
共 23 条
[1]   Two beam cross correlation:: A method to characterize transport phenomena in micrometer-sized structures [J].
Brinkmeier, M ;
Dörre, K ;
Stephan, J ;
Eigen, M .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :609-616
[2]   Four-color fluorescence correlation spectroscopy realized in a grating-based detection platform [J].
Burkhardt, M ;
Heinze, KG ;
Schwille, P .
OPTICS LETTERS, 2005, 30 (17) :2266-2268
[3]   Measuring fast dynamics in solutions and cells with a laser scanning microscope [J].
Digman, MA ;
Brown, CM ;
Sengupta, P ;
Wiseman, PW ;
Horwitz, AR ;
Gratton, E .
BIOPHYSICAL JOURNAL, 2005, 89 (02) :1317-1327
[4]   Spatial two-photon fluorescence cross-correlation Spectroscopy for controlling molecular transport in microfluidic structures [J].
Dittrich, PS ;
Schwille, P .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4472-4479
[5]   Parallel dual-color fluorescence cross-correlation spectroscopy using diffractive optical elements -: art. no. 054008 [J].
Gösch, M ;
Blom, H ;
Anderegg, S ;
Korn, K ;
Thyberg, P ;
Wells, M ;
Lasser, T ;
Rigler, R .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (05)
[6]   Parallel single molecule detection with a fully integrated single-photon 2X2 CMOS detector array [J].
Gösch, M ;
Serov, A ;
Anhut, T ;
Lasser, T ;
Rochas, A ;
Besse, PA ;
Popovic, RS ;
Blom, H ;
Rigler, R .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (05) :913-921
[7]   Fluorescence correlation spectroscopy of molecular motions and kinetics [J].
Gösch, M ;
Rigler, R .
ADVANCED DRUG DELIVERY REVIEWS, 2005, 57 (01) :169-190
[8]   Hydrodynamic flow profiling in microchannel structures by single molecule fluorescence correlation spectroscopy [J].
Gösch, M ;
Blom, H ;
Holm, J ;
Heino, T ;
Rigler, R .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3260-3265
[9]   Triple-color coincidence analysis: One step further in following higher order molecular complex formation [J].
Heinze, KG ;
Jahnz, M ;
Schwilley, P .
BIOPHYSICAL JOURNAL, 2004, 86 (01) :506-516
[10]  
HWANG LC, IN PRESS OPT LETT