Diffractive imaging of highly focused X-ray fields

被引:178
作者
Quiney, HM
Peele, AG
Cai, Z
Paterson, D
Nugent, KA [1 ]
机构
[1] Univ Melbourne, Sch Phys, Melbourne, Vic 3010, Australia
[2] La Trobe Univ, Dept Phys, Bundoora, Vic 3086, Australia
[3] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
D O I
10.1038/nphys218
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The rapid development of new sources of coherent X-rays, such as third-generation synchrotrons, high-harmonic-generation lasers' and X-ray free-electron lasers', has led to the emergence of the new field of X-ray coherent science. The extension of coherent methods to the X-ray regime makes possible methods such as coherent diffraction, X-ray photoncorrelation spectroscopy, speckle interferometry and ultrafast probing at atomic resolution and femtosecond timescales. Despite rapid improvements in the resolution that conventional X-ray optics can achieve, new methods for manipulating X-rays are required to push this to the atomic scale(3). Here we demonstrate a coherent imaging technique that enables us to image the complex field at the focus of an X-ray zone plate without the need for conventional X-ray lenses. There are no fundamental limits on the resolution of this lensless imaging technique other than the wavelength of the X-rays themselves. The ability to characterize the beam with one measurement makes the method ideally suited to characterizing the fields generated by pulsed coherent X-ray sources.
引用
收藏
页码:101 / 104
页数:4
相关论文
共 17 条
[1]  
BATES RHT, 1982, OPTIK, V61, P247
[2]   An X-ray FEL laboratory as part of a linear collider design [J].
Brinkmann, R ;
Materlik, G ;
Rossbach, J ;
Schneider, JR ;
Wiik, BH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 393 (1-3) :86-92
[3]   Soft X-ray microscopy at a spatial resolution better than 15nm [J].
Chao, WL ;
Harteneck, BD ;
Liddle, JA ;
Anderson, EH ;
Attwood, DT .
NATURE, 2005, 435 (7046) :1210-1213
[4]   Phase-retrieval X-ray microscopy by Wigner-distribution deconvolution [J].
Chapman, HN .
ULTRAMICROSCOPY, 1996, 66 (3-4) :153-172
[5]   HUBBLE SPACE TELESCOPE CHARACTERIZED BY USING PHASE-RETRIEVAL ALGORITHMS [J].
FIENUP, JR ;
MARRON, JC ;
SCHULZ, TJ ;
SELDIN, JH .
APPLIED OPTICS, 1993, 32 (10) :1747-1767
[6]   PHASE RETRIEVAL ALGORITHMS - A COMPARISON [J].
FIENUP, JR .
APPLIED OPTICS, 1982, 21 (15) :2758-2769
[7]   PHASE-RETRIEVAL ALGORITHMS FOR A COMPLICATED OPTICAL-SYSTEM [J].
FIENUP, JR .
APPLIED OPTICS, 1993, 32 (10) :1737-1746
[8]  
GERCHBERG RW, 1972, OPTIK, V35, P237
[9]   Measurement of the spatial coherence function of undulator radiation using a phase mask [J].
Lin, JJA ;
Paterson, D ;
Peele, AG ;
McMahon, PJ ;
Chantler, CT ;
Nugent, KA ;
Lai, B ;
Moldovan, N ;
Cai, Z ;
Mancini, DC ;
McNulty, I .
PHYSICAL REVIEW LETTERS, 2003, 90 (07) :4
[10]   X-ray image reconstruction from a diffraction pattern alone [J].
Marchesini, S ;
He, H ;
Chapman, HN ;
Hau-Riege, SP ;
Noy, A ;
Howells, MR ;
Weierstall, U ;
Spence, JCH .
PHYSICAL REVIEW B, 2003, 68 (14)