Use of ionic polymers as stationary and pseudo-stationary phases in the separation of ions by capillary electrophoresis and capillary electrochromatography

被引:27
作者
Fritz, JS
Breadmore, MC
Hilder, EF
Haddad, PR
机构
[1] Iowa State Univ Sci & Technol, Dept Chem, Ames, IA 50011 USA
[2] Iowa State Univ Sci & Technol, Ames Lab, Ames, IA 50011 USA
[3] Univ Tasmania, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
reviews; ion chromatography-capillary electrophoresis; electrochromatography; stationary phases; capillary electrophoresis-ion chromatography; inorganic anions; organic acids; inorganic cations;
D O I
10.1016/S0021-9673(01)01403-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
One of the problems with capillary electrophoresis is a lack of versatility regarding manipulation of the separation selectivity. A new and potentially universal concept is to introduce an ion-exchange component into a separation so that the migration of analyte ions is influenced by both their electrophoretic mobilities and their chromatographic properties. This may be accomplished by use of capillaries filled with or coated with solid ion-exchange polymers, or by addition of a soluble ionic polymer to the background electrolyte to create a pseudo-stationary phase. While each of these methods achieves the same result, they are not competitive, but rather complementary as the problems associated by one approach are overcome by the others. Recent highlights in the field are used to illustrate the flexibility that this approach provides to electrophoretic separation of ions. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:11 / 32
页数:22
相关论文
共 60 条
[1]   STUDIES ON THE DETERMINATION OF INORGANIC ANIONS BY CAPILLARY ELECTROPHORESIS [J].
BENZ, NJ ;
FRITZ, JS .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :437-443
[2]   Open-tubular ion-exchange capillary electrochromatography of inorganic anions [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYST, 2000, 125 (07) :1235-1241
[3]   Optimisation of the separation of anions by ion chromatography-capillary electrophoresis using indirect UV detection [J].
Breadmore, MC ;
Haddad, PR ;
Fritz, JS .
JOURNAL OF CHROMATOGRAPHY A, 2001, 920 (1-2) :31-40
[4]   Determination of inorganic anions by capillary electrochromatography [J].
Breadmore, MC ;
Hilder, EF ;
Macka, M ;
Haddad, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (6-7) :355-364
[5]   Peak shapes in open tubular ion-exchange capillary electrochromatography of inorganic anions [J].
Breadmore, MC ;
Boyce, M ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :303-313
[6]  
Breadmore MC, 2000, ELECTROPHORESIS, V21, P3181, DOI 10.1002/1522-2683(20000901)21:15<3181::AID-ELPS3181>3.0.CO
[7]  
2-L
[8]   EFFECTS OF CARRIER ELECTROLYTE-COMPOSITION ON SEPARATION SELECTIVITY IN CAPILLARY ZONE ELECTROPHORESIS OF LOW-MOLECULAR-MASS ANIONS [J].
BUCHBERGER, W ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :59-64
[9]   Resin coating for capillaries giving a net positive charge and great potential for customised modification of surface properties [J].
Burt, H ;
Lewis, DM ;
Tapley, KN .
JOURNAL OF CHROMATOGRAPHY A, 1996, 739 (1-2) :367-371
[10]   Poly(vinylamine)-coated capillaries with reversed electroosmotic flow for the separation of organic anions [J].
Chiari, M ;
Ceriotti, L ;
Crini, G ;
Morcellet, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (01) :81-91