The effect of pedicle morphometry on pedicle screw loading - A synthetic model

被引:38
作者
McKinley, TO
McLain, RF
Yerby, SA
SarigulKlijn, N
Smith, TS
机构
[1] UNIV CALIF DAVIS, DEPT ORTHOPAED SURG, SACRAMENTO, CA 95817 USA
[2] UNIV CALIF DAVIS, DEPT AERONAUT ENGN, SACRAMENTO, CA 95817 USA
[3] UNIV CALIF DAVIS, ORTHOPAED RES LABS, SACRAMENTO, CA 95817 USA
关键词
biomechanics; pedicle screw; spinal fusion; spinal instrumentation;
D O I
10.1097/00007632-199702010-00003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Static nondestructive bending analysis of pedicle screws inserted into vertebral analogues was conducted, Pedicle screw bending load was studied as a function of pedicle morphometry. Objectives. To determine how sagittal bending moment in pedicle screws is affected by changes in pedicle height, length, and width. Background Data. An unexpectedly high rate of clinical failure has been observed in pedicle screws used in short-segment instrumentation for axially unstable fractures. The majority of screws fail in sagittal bending within the pedicle. To date, little is known of the exogenous factors that affect in situ loads incurred by pedicle screws. Methods. Synthetic vertebral analogues were fabricated, varying pedicle height, length, or width independently. Pedicle screws internally instrumented with strain gages were used as load transducers to determine screw bending moments within the pedicle and body of the analogue. Analogues were loaded in compression to simulate loading of an unstable burst fracture. Results. Screw bending moments within the pedicle increased incrementally with increasing pedicle length, rising 30% as length increased from 8.0 mm to 12.0 mm. Screw moment increased 20% when pedicle height dropped below 15.0 mm, consistent with a threshold effect. Changes in pedicle width did not affect screw loads within the pedicle. Conclusions. In situ pedicle screw loads increased significantly as pedicle length increased and as pedicle height decreased. Pedicle screws instrumented internally with strain gages are an effective research instrument allowing measurement of in situ loading along the axis of the screw.
引用
收藏
页码:246 / 252
页数:7
相关论文
共 46 条
[1]
BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL [J].
ASHMAN, RB ;
GALPIN, RD ;
CORIN, JD ;
JOHNSTON, CE .
SPINE, 1989, 14 (12) :1398-1405
[2]
ASHMAN RB, 1988, CLIN ORTHOP RELAT R, P113
[3]
A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE [J].
BERRY, JL ;
MORAN, JM ;
BERG, WS ;
STEFFEE, AD .
SPINE, 1987, 12 (04) :362-367
[4]
CARL AL, 1992, SPINE, V17, pS317
[5]
THE ELASTIC-MODULI OF HUMAN SUBCHONDRAL, TRABECULAR, AND CORTICAL BONE TISSUE AND THE SIZE-DEPENDENCY OF CORTICAL BONE MODULUS [J].
CHOI, K ;
KUHN, JL ;
CIARELLI, MJ ;
GOLDSTEIN, SA .
JOURNAL OF BIOMECHANICS, 1990, 23 (11) :1103-1113
[6]
A COMPARISON OF THE FATIGUE BEHAVIOR OF HUMAN TRABECULAR AND CORTICAL BONE TISSUE [J].
CHOI, K ;
GOLDSTEIN, SA .
JOURNAL OF BIOMECHANICS, 1992, 25 (12) :1371-1381
[7]
AN ANATOMICAL COMPARISON OF THE HUMAN AND BOVINE THORACOLUMBAR SPINE [J].
COTTERILL, PC ;
KOSTUIK, JP ;
DANGELO, G ;
FERNIE, GR ;
MAKI, BE .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (03) :298-303
[8]
STATIC AND CYCLICAL BIOMECHANICAL ANALYSIS OF PEDICLE SCREW SPINAL CONSTRUCTS [J].
CUNNINGHAM, BW ;
SEFTER, JC ;
SHONO, Y ;
MCAFEE, PC .
SPINE, 1993, 18 (12) :1677-1688
[9]
APPLICATION OF POSTERIOR PLATING AND MODIFICATIONS IN THORACOLUMBAR SPINE INJURIES - INDICATION, TECHNIQUES, AND RESULTS [J].
DANIAUX, H ;
SEYKORA, P ;
GENELIN, A ;
LANG, T ;
KATHREIN, A .
SPINE, 1991, 16 (03) :S125-S133
[10]
LONGITUDINAL ELEMENT SIZE EFFECT ON LOAD SHARING, INTERNAL LOADS, AND FATIGUE LIFE OF TRI-LEVEL SPINAL IMPLANT CONSTRUCTS [J].
DUFFIELD, RC ;
CARSON, WL ;
CHEN, LY ;
VOTH, B .
SPINE, 1993, 18 (12) :1695-1703