Detection of tricyclic antidepressants in whole blood by headspace solid-phase microextraction and capillary gas chromatography

被引:65
作者
Lee, XP
Kumazawa, T
Sato, K
Suzuki, O
机构
[1] SHOWA UNIV, SCH MED, DEPT LEGAL MED, SHINAGAWA KU, TOKYO 142, JAPAN
[2] HAMAMATSU UNIV SCH MED, DEPT LEGAL MED, HAMAMATSU, SHIZUOKA 43131, JAPAN
关键词
D O I
10.1093/chromsci/35.7.302
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple method for the extraction of four tricyclic antidepressants from whole blood by headspace solid-phase microextraction (SPME) is presented. The whole blood samples contain four drugs (amitriptyline, chlorimipramine, imipramine, and trimipramine) and are heated at 100°C in a septum-capped vial in the presence of distilled water and NaOH solution; a polydimethylsiloxane-coated SPME fiber is exposed to the headspace of the vial to allow adsorption of the drugs before capillary gas chromatography (GC) with flame-ionization detection. The headspace SPME-GC produces intense peaks for each drug with very little background noise. Recoveries of the four drugs by the present method are 5.3-12.9%. The calibration curves for the drugs show linearity in the range of 31-1000 ng/0.5 ml. The detection limits of each drug are 16-25 ng/0.5 mL. Imipramine is detectable from rat blood 5 h after oral administration of imipramine (500 mg/kg body weight); the concentration is 1.44 ± 0.209 μg/mL.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 20 条
  • [1] SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS
    ARTHUR, CL
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (19) : 2145 - 2148
  • [2] CHRISTMORE DS, 1984, J FORENSIC SCI, V29, P1038
  • [3] NEW SENSITIVE AND SELECTIVE DETECTOR FOR GAS-CHROMATOGRAPHY - SURFACE-IONIZATION DETECTOR WITH A HOT PLATINUM EMITTER
    FUJII, T
    ARIMOTO, H
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (13) : 2625 - 2628
  • [4] SENSITIVE DETERMINATION OF PHENOTHIAZINES IN BODY-FLUIDS BY GAS-CHROMATOGRAPHY WITH SURFACE-IONIZATION DETECTION
    HATTORI, H
    YAMAMOTO, S
    IWATA, M
    TAKASHIMA, E
    YAMADA, T
    SUZUKI, O
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 579 (02): : 247 - 252
  • [5] COMPONENTS OF PAINT THINNER IN BODY-FLUIDS CLEARLY DETECTED USING THE SALTING-OUT TECHNIQUE
    KATO, K
    NAGATA, T
    KIMURA, K
    KUDO, K
    IMAMURA, T
    NODA, M
    [J]. FORENSIC SCIENCE INTERNATIONAL, 1990, 44 (01) : 55 - 60
  • [6] Detection of ethanol in human body fluids by headspace solid-phase micro extraction (SPME) capillary gas chromatography
    Kumazawa, T
    Seno, H
    Lee, XP
    Ishii, A
    Suzuki, O
    Sato, K
    [J]. CHROMATOGRAPHIA, 1996, 43 (7-8) : 393 - 397
  • [7] Extraction of local anaesthetics from human blood by direct immersion solid phase micro extraction (SPME)
    Kumazawa, T
    Sato, K
    Seno, H
    Ishii, A
    Suzuki, O
    [J]. CHROMATOGRAPHIA, 1996, 43 (1-2) : 59 - 62
  • [8] Kumazawa T., 1995, JPN J FORENSIC TOXIC, V13, P207
  • [9] A SIMPLE ANALYSIS OF 5 THINNER COMPONENTS IN HUMAN-BODY FLUIDS BY HEADSPACE SOLID-PHASE MICROEXTRACTION (SPME)
    LEE, XP
    KUMAZAWA, T
    SATO, K
    [J]. INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 1995, 107 (06) : 310 - 313
  • [10] Detection of organophosphate pesticides in human body fluids by headspace solid-phase microextraction (SPME) and capillary gas chromatography with nitrogen-phosphorus detection
    Lee, XP
    Kumazawa, T
    Sato, K
    Suzuki, O
    [J]. CHROMATOGRAPHIA, 1996, 42 (3-4) : 135 - 140