A focused ultrasound method for simultaneous diagnostic and therapeutic applications - a simulation study

被引:74
作者
Konofagou, E [1 ]
Thierman, J [1 ]
Hynynen, K [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol,Ultrasound Lab MRI Res, Boston, MA 02115 USA
关键词
D O I
10.1088/0031-9155/46/11/314
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Similar to other therapeutic methods, ultrasound surgery requires an imaging modality to monitor the extent of tissue damage during treatment. In this paper, we have considered the method of ultrasound-stimulated acoustic emission (USAE) that uses two ultrasonic beams at high frequency (1.7 MHz) (same as that used for ablation) to locally excite the tissue by generating a low-frequency (1-50 kHz) radiation force. Recording of the tissue response at several locations yields an image. The amplitude of the tissue response depends on the mechanical and acoustic tissue properties, namely its stiffness and absorption. These two properties were initially hypothesized to have counteractive effects on the response amplitude, i.e., the amplitude should increase with absorption and decrease with stiffness. To check this hypothesis as well as the degree to which these properties influence the response, finite-element simulations of a uniform lesion formed inside a homogeneous medium were used. The results show that, as expected, the displacement amplitude decreased with increasing lesion stiffness at lower frequencies (except at resonance) while, contrary to our initial hypothesis, it increased with stiffness at relatively higher frequencies (>22 kHz). At resonance, a frequency upshift occurred with increasing stiffness but was found to be highly spatially variant and system dependent, i.e., not yielding a uniform lesion response when imaged. On the other hand, the absorption increase led to a uniform linear increase of the mechanical response amplitude of the lesion. Therefore, at higher frequencies, increase of the two parameters had a synergistic effect on the tissue response to the applied radiation force. This study showed that relatively higher frequencies constitute the optimal range in the use of USAE for coagulation monitoring. A preliminary experimental verification in vitro is also provided.
引用
收藏
页码:2967 / 2984
页数:18
相关论文
共 36 条
[1]  
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P149, DOI 10.1016/0301-5629(79)90083-8
[2]   ACOUSTIC PROPERTIES OF LESIONS GENERATED WITH AN ULTRASOUND THERAPY SYSTEM [J].
BUSH, NL ;
RIVENS, I ;
TERHAAR, GR ;
BAMBER, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :789-801
[3]   ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO [J].
CESPEDES, I ;
OPHIR, J ;
PONNEKANTI, H ;
MAKLAD, N .
ULTRASONIC IMAGING, 1993, 15 (02) :73-88
[4]  
DOYLEY MM, 1999, IEEE UFFC S LAK TAH
[5]   Application of radiation force in noncontact measurement of the elastic parameters [J].
Fatemi, M ;
Greenleaf, JF .
ULTRASONIC IMAGING, 1999, 21 (02) :147-154
[6]   Ultrasound-stimulated vibro-acoustic spectrography [J].
Fatemi, M ;
Greenleaf, JF .
SCIENCE, 1998, 280 (5360) :82-85
[7]  
FRY F J, 1978, Ultrasound in Medicine and Biology, V4, P337, DOI 10.1016/0301-5629(78)90022-4
[8]   DETERMINATION OF ABSOLUTE SOUND LEVELS AND ACOUSTIC ABSORPTION COEFFICIENTS BY THERMOCOUPLE PROBES - THEORY [J].
FRY, WJ ;
FRY, RB .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1954, 26 (03) :294-310
[9]   Elastography of breast lesions: Initial clinical results [J].
Garra, BS ;
Cespedes, EI ;
Ophir, J ;
Spratt, SR ;
Zuurbier, RA ;
Magnant, CM ;
Pennanen, MF .
RADIOLOGY, 1997, 202 (01) :79-86
[10]   DEMONSTRATION OF ENHANCED TEMPERATURE ELEVATION DUE TO NONLINEAR PROPAGATION OF FOCUSED ULTRASOUND IN DOGS THIGH INVIVO [J].
HYNYNEN, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (02) :85-91