Stability Analysis of Grid-Connected Inverter With LCL Filter Adopting a Digital Single-Loop Controller With Inherent Damping Characteristic

被引:150
作者
Yin, Jinjun [1 ]
Duan, Shanxu [1 ]
Liu, Bangyin [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Grid-connected inverter; LCL filter; single-loop digital controller; stability analysis; VOLTAGE-SOURCE CONVERTER; PWM CONVERTERS; DESIGN;
D O I
10.1109/TII.2012.2222424
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The stability problem of the grid-connected inverter with LCL filter adopting a digital single-loop controller without extra damping resistance is analyzed. The digital single-loop control based on the grid-side current feedback can attenuate the resonance introduced by LCL filters due to the inherent damping characteristic embedded in the control loop. The stability analysis is performed by means of a Nyquist diagram in the discrete domain and to provide a general design direction for filter and controller. The quantitative relationship of ratios of LCL resonance angular frequency to control frequency and controller parameters on the system stability is investigated. It is derived that the system would obtain preferable stability margin when the ratio is located at a certain range. The theoretical analyses are validated by experimental tests based on a 5-kW single-phase inverter laboratory prototype.
引用
收藏
页码:1104 / 1112
页数:9
相关论文
共 26 条
  • [1] A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter
    Blasko, V
    Kaura, V
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) : 542 - 550
  • [2] Bojoi R., 2008, IECON 2008 - 34th Annual Conference of IEEE Industrial Electronics Society, P3141, DOI 10.1109/IECON.2008.4758463
  • [3] PI State Space Current Control of Grid-Connected PWM Converters With LCL Filters
    Dannehl, Joerg
    Fuchs, Friedrich Wilhelm
    Thogersen, Paul Bach
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (09) : 2320 - 2330
  • [4] Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters
    Dannehl, Joerg
    Fuchs, Friedrich Wilhelm
    Hansen, Steffan
    Thogersen, Paul Bach
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (04) : 1509 - 1517
  • [5] Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With LCL Filters
    Dannehl, Joerg
    Wessels, Christian
    Fuchs, Friedrich Wilhelm
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) : 380 - 388
  • [6] Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter
    Gabe, Ivan Jorge
    Montagner, Vinicius Foletto
    Pinheiro, Humberto
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) : 1444 - 1452
  • [7] Frequency-domain passivity-based current controller design
    Harnefors, L.
    Zhang, L.
    Bongiorno, M.
    [J]. IET POWER ELECTRONICS, 2008, 1 (04) : 455 - 465
  • [8] DSP-Based Control of Grid-Connected Power Converters Operating Under Grid Distortions
    Kazmierkowski, Marian P.
    Jasinski, Marek
    Wrona, Grzegorz
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2011, 7 (02) : 204 - 211
  • [9] Lindgren M, 1998, IEEE POWER ELECTRON, P229, DOI 10.1109/PESC.1998.701904
  • [10] Design and control of an LCL-filter-based three-phase active rectifier
    Liserre, M
    Blaabjerg, F
    Hansen, S