Ultrasound-guided near-nerve neurography for early evaluation of nerve regeneration

被引:9
作者
de Kool, B. S. [1 ,2 ]
Blok, Joleen H. [1 ]
Walbeehm, Erik T. [2 ]
van Neck, Johan W. [2 ]
Hovius, Steven E. R. [2 ]
Visser, Gerhard H. [1 ]
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Clin Neurophysiol, NL-3000 CA Rotterdam, Netherlands
[2] Univ Med Ctr Rotterdam, Erasmus MC, Dept Plast & Reconstruct Surg, NL-3000 CA Rotterdam, Netherlands
关键词
Early evaluation; Intra-operative neurography; Near-nerve neurography; Needle electrode placement; Nerve regeneration; Ultrasound;
D O I
10.1016/j.jneumeth.2008.07.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For early assessment of axonal outgrowth after trauma, the nerve is surgically exposed to enable compound nerve action potential (CNAP) recordings across the lesion site. Near-nerve neurography, with needle electrodes placed transcutaneously near the nerve, could be a minimally invasive alternative if the needle placement procedure and low reproducibility are improved. We developed ultrasound-guided near-nerve neurography, which facilitates needle placement, and assessed its potential for evaluating nerve regeneration. Measurements were performed at varying times after crush lesion of the peroneal nerve of 25 rabbits. To test if ultrasound-guided near-nerve signals could be measured prior to muscle reinnervation, they were compared with recordings of compound muscle action potentials. A comparison with conventional intra-operative CNAP recordings was made by measuring nerve signal amplitude with both techniques and by assessing reproducibility. In all cases where intra-operative signals could be measured, near-nerve signals were also detected. Compound nerve activity could be recorded after 5 weeks, whereas compound muscle activity appeared after approximately 8 weeks. Reproducibility was slightly better for near-nerve than for intra-operative recordings. We conclude that ultrasound-guided near-nerve neurography is able to assess nerve regeneration well before compound muscle activity can be detected. Its accuracy and reproducibility are similar to those of conventional intra-operative recordings. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 21 条
[1]   A COLLAGEN-BASED NERVE GUIDE CONDUIT FOR PERIPHERAL-NERVE REPAIR - AN ELECTROPHYSIOLOGICAL STUDY OF NERVE REGENERATION IN RODENTS AND NONHUMAN-PRIMATES [J].
ARCHIBALD, SJ ;
KRARUP, C ;
SHEFNER, J ;
LI, ST ;
MADISON, RD .
JOURNAL OF COMPARATIVE NEUROLOGY, 1991, 306 (04) :685-696
[2]  
Buchthal F., 1966, Brain Res, V3, P1
[3]   Ultrasound imaging of the rabbit peroneal nerve [J].
de Kool, BS ;
van Neck, JW ;
Blok, JH ;
Walbeehm, ET ;
Hekking, I ;
Visser, GH .
JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2005, 10 (04) :369-374
[4]   Sciatic function index, nerve conduction tests, muscle contraction, and axon morphometry as indicators of regeneration [J].
Kanaya, F ;
Firrell, JC ;
Breidenbach, WC .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 98 (07) :1264-1271
[5]   A QUARTER CENTURY EXPERIENCE WITH INTRAOPERATIVE NERVE ACTION-POTENTIAL RECORDING [J].
KLINE, DG ;
HAPPEL, LT .
CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1993, 20 (01) :3-10
[6]  
KLINE DG, 1968, SURG GYNECOL OBSTETR, V127, P1239
[7]   Factors that influence peripheral nerve regeneration: An electrophysiological study of the monkey median nerve [J].
Krarup, C ;
Archibald, SJ ;
Madison, RD .
ANNALS OF NEUROLOGY, 2002, 51 (01) :69-81
[8]  
LUDIN HP, 1981, SENSORY NEUROGRAPHY
[9]  
Lundborg G, 1970, Scand J Plast Reconstr Surg Suppl, V6, P3
[10]   A 25-year perspective of peripheral nerve surgery: Evolving neuroscientific concepts and clinical significance [J].
Lundborg, G .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (03) :391-414