PICsIT: a position sensitive detector for space applications

被引:8
作者
Labanti, C
Di Cocco, G
Malaguti, G
Stephen, JB
Rossi, E
Schiavone, F
Traci, A
Ferro, G
Ferriani, S
Mauri, A
Visparelli, D
机构
[1] CNR, Ist TeSRE, I-40029 Bologna, Italy
[2] ENEA, CR E Clementel, Bologna, Italy
关键词
gamma-ray telescopes; scintillation detectors; photodiodes; ASIC;
D O I
10.1016/S0168-9002(01)01923-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Pixellated Imaging CsI Telescope (PICsIT) is the high energy detector plane of Imager on Board INTEGRAL Satellite (IBIS), one of the main instruments on board the International Gamma-Ray Astrophysics Laboratory (INTEGRAL) satellite that will be launched in the year 2001. It consists of 4096 CsI(T1) individual detector elements and operates in the energy range from 120 to 10,000 keV. PICsIT is made up of 8 identical modules, each housing 512 scintillating crystals coupled to PIN photodiodes (PD). Each crystal, 30 mm long and with a cross-section of 8.55 x 8.55 mm(2), is wrapped with a white diffusing coating and then inserted into an aluminium crate. In order to have a compact design, two electronic boards, mounted directly below the crystal/PD assembly, host both the Analogue and it, Digital Front-End Electronics (FEE). The behaviour of the read-out FEE has a direct impact on the performance of the whole detector in terms of lower energy threshold, energy resolution and event time tagging. Due to the great number of channels to be handled, an Application Specific Integrated Circuit (ASIC), that manages signals coming from groups of 16 detecting units, has been designed. The first reduced model of a PICsIT module has been now constructed and is under intensive tests in order to evaluate the main qualification parameters of the detector. In this paper, after a description of the PICsIT hardware and assembly procedures, the main results on system functionality are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:561 / 566
页数:6
相关论文
共 4 条
[1]   The scientific calibration of the PICsIT Engineering Model detector of the IBIS telescope [J].
Di Cocco, G ;
Malaguti, G ;
Pinazza, O ;
Schiavone, F ;
Stephen, JB ;
Ferro, G ;
Labanti, C ;
Spizzichino, A ;
Trifoglio, M ;
Caroli, E .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 :33-41
[2]  
LABANTI C, 1998, IEEE NSS C REC TOR
[3]   Performances of detector elements for PICsIT: the high energy detector plane of the IBIS instrument on board the INTEGRAL satellite. [J].
Rossi, E ;
Cavazzuti, E ;
Di Cocco, G ;
Ferro, G ;
Labanti, C ;
Mauri, A ;
Schiavone, F ;
Schotanus, P ;
Traci, A .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 :578-583
[4]   The Science Test Equipment for the INTEGRAL-PICsIT instrument. [J].
Trifoglio, M ;
Gianotti, F ;
Stephen, JB ;
Ferro, G ;
Visparelli, D .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 :572-581