Heparin-bonded surfaces in extracorporeal membrane oxygenation for cardiac support

被引:23
作者
vonSegesser, LK
机构
关键词
D O I
10.1016/0003-4975(95)01011-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Development of increasingly complex perfusion devices with bonded heparin allowed for significant improvement of thromboresistance of most basic components required for cardiopulmonary bypass. In his recent review of heparin-coated cardiopulmonary bypass circuits, Gravlee cited 91 references dealing with heparin-coated surfaces, and far more can be found if the search includes material technology or heparin-coated devices not designed for cardiopulmonary bypass (eg, ventricular assist devices, hemofilters, catheters). The present review is focused on long-term application of heparin-coated equipment in conjunction with basic work on heparin bonding relevant for extracorporeal membrane oxygenation. Experimental open chest cardiopulmonary bypass using heparin-coated equipment without systemic heparinization up to 36 hours has shown improved thromboresistance, and better platelet preservation was demonstrated for perfusion with heparin-coated cardiopulmonary bypass equipment up to 5 days in the experimental set-up. Similar findings were reported for roller pump perfusion with heparin-coated tubing and centrifugal pump perfusion with heparin-coated pump heads. More recently, heparin bonding was also made available for oxygenators with true membranes that preclude plasma leakage. The available knowledge on clinical applications of heparin-coated perfusion equipment is mainly based on short-term applications like ours, which now includes more than 300 patients. Reduced postoperative blood loss and as a result fewer transfusions were the main benefits of heparin-coated equipment allowing for perfusion with low systemic heparinization. There are only a few reports on long-term use of heparin-coated equipment for prolonged circulatory support. However, the longest clinical application of a single device is that of an intravascular gas exchanger that remained fully functional during a 29-day implantation period. Finally, it appears, that circulating protamine interacts with surface-bound heparin. Protamine administration should therefore be avoided during perfusion with heparin-bonded equipment to maintain the improved thromboresistance.
引用
收藏
页码:330 / 335
页数:6
相关论文
共 28 条
  • [1] Bianchi J J, 1992, ASAIO J, V38, pM143, DOI 10.1097/00002480-199207000-00005
  • [2] TREATMENT OF ACUTE RESPIRATORY-FAILURE BY EXTRACORPOREAL CARBON-DIOXIDE ELIMINATION PERFORMED WITH A SURFACE HEPARINIZED ARTIFICIAL LUNG
    BINDSLEV, L
    EKLUND, J
    NORLANDER, O
    SWEDENBORG, J
    OLSSON, P
    NILSSON, E
    LARM, O
    GOUDA, I
    MALMBERG, A
    SCHOLANDER, E
    [J]. ANESTHESIOLOGY, 1987, 67 (01) : 117 - 120
  • [3] GOTT VL, 1963, SCIENCE, V142, P1297, DOI 10.1126/science.142.3597.1297
  • [4] Gravlee G P, 1994, J Cardiothorac Vasc Anesth, V8, P213, DOI 10.1016/1053-0770(94)90066-3
  • [5] KLEIN MD, 1990, J THORAC CARDIOV SUR, V100, P498
  • [6] Lazzara R R, 1993, ASAIO J, V39, pM444
  • [7] Marcolin R, 1991, ASAIO Trans, V37, P584
  • [8] Matsuwaka R, 1990, ASAIO Trans, V36, pM473
  • [9] MORTENSEN JD, 1987, T AM SOC ART INT ORG, V33, P570
  • [10] Mottaghy K, 1989, ASAIO Trans, V35, P635, DOI 10.1097/00002480-198907000-00152