Characterization of vaccinia virus particles using microscale silicon cantilever resonators and atomic force microscopy

被引:82
作者
Johnson, L
Gupta, ATK
Ghafoor, A
Akin, D
Bashir, R [1 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, Sch Elect & Comp Engn, Birck Nanotechnol Ctr, W Lafayette, IN 47907 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, Sch Elect & Comp Engn, Bindleyl Biosci Ctr, W Lafayette, IN 47907 USA
基金
美国国家卫生研究院; 美国国家航空航天局; 美国国家科学基金会;
关键词
bioMEMS; cantilever sensors; resonant sensors;
D O I
10.1016/j.snb.2005.08.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid means of characterizing and detecting virus particles are very important for a wide variety of applications. We have used vaccinia virus, a member of the Poxviridae virus family and the basis of the smallpox vaccine, as the test case and characterized these particles using atomic force microscopy and micron-scale cantilever beams, with the long-term goal of developing devices for the direct rapid detection of air-borne virus particles. The cantilever beams, driven by thermal noise and a PZT piezoelectric ceramic, served as resonating sensors to measure the mass of these virus particles. Two different size cantilevers were used, with dimensions of 21 mu m x 9 mu m and 6 mu m x 4 mu m. All cantilevers measured approximately 200 nm in thickness. The resonant frequency spectra of the cantilevers were measured using a microscope scanning laser Doppler vibrometer before and after the addition of virus particles, and scanning electron micrographs were taken in order to quantify the number of virus particles attached to the cantilevers. The change in resonant frequency as a function of the number of adsorbed virus particles was the basis of the mass detection scheme. We have measured the average mass of a single vaccinia virus particle to be 12.4 +/- 1.3 fg and 7.9 +/- 4.6 fg, obtained from the larger and smaller cantilever beams, respectively, which is in the expected range of 5-10 fg. The measurable mass sensitivity of cantilevers driven by the piezoelectric ceramic is found to be an order of magnitude greater than the sensitivity of cantilevers driven by thermal noise. These cantilever structures can be integral parts of biosensors for the detection of airborne virus particles. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 25 条
[1]   FREQUENCY-MODULATION DETECTION USING HIGH-Q CANTILEVERS FOR ENHANCED FORCE MICROSCOPE SENSITIVITY [J].
ALBRECHT, TR ;
GRUTTER, P ;
HORNE, D ;
RUGAR, D .
JOURNAL OF APPLIED PHYSICS, 1991, 69 (02) :668-673
[2]   Immunoassay of infectious agents [J].
Andreotti, PE ;
Ludwig, GV ;
Peruski, AH ;
Tuite, JJ ;
Morse, SS ;
Peruski, LF .
BIOTECHNIQUES, 2003, 35 (04) :850-859
[3]  
[Anonymous], 1990, Virology, DOI DOI 10.1016/0042-6822(90)90294-2
[4]   VARIABILITY OF DRY MASS AS A FUNDAMENTAL BIOLOGICAL PROPERTY DEMONSTRATED FOR THE CASE OF VACCINIA VIRIONS [J].
BAHR, GF ;
FOSTER, WD ;
PETERS, D ;
ZEITLER, EH .
BIOPHYSICAL JOURNAL, 1980, 29 (02) :305-314
[5]   Vaccinia virus transcription [J].
Broyles, SS .
JOURNAL OF GENERAL VIROLOGY, 2003, 84 :2293-2303
[6]   ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS [J].
CHEN, GY ;
THUNDAT, T ;
WACHTER, EA ;
WARMACK, RJ .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) :3618-3622
[7]   BIOGENESIS OF VACCINIA - EVIDENCE FOR MORE THAN 100 POLYPEPTIDES IN THE VIRION [J].
ESSANI, K ;
DALES, S .
VIROLOGY, 1979, 95 (02) :385-394
[8]   THE COMPLETE DNA-SEQUENCE OF VACCINIA VIRUS [J].
GOEBEL, SJ ;
JOHNSON, GP ;
PERKUS, ME ;
DAVIS, SW ;
WINSLOW, JP ;
PAOLETTI, E .
VIROLOGY, 1990, 179 (01) :247-266
[9]   Structure and assembly of intracellular mature vaccinia virus: Isolated-particle analysis [J].
Griffiths, G ;
Wepf, R ;
Wendt, T ;
Locker, JK ;
Cyrklaff, M ;
Roos, N .
JOURNAL OF VIROLOGY, 2001, 75 (22) :11034-11055
[10]   Single virus particle mass detection using microresonators with nanoscale thickness [J].
Gupta, A ;
Akin, D ;
Bashir, R .
APPLIED PHYSICS LETTERS, 2004, 84 (11) :1976-1978