Behaviour of ChronOS™ Inject in metaphyseal bone defects of distal radius fractures: Tissue reaction after 6-15 months

被引:5
作者
Arora, Rohit [1 ]
Milz, Stefan [2 ,3 ]
Sprecher, Christoph [2 ]
Sitte, Ingrid [1 ]
Blauth, Michael [1 ]
Lutz, Martin [1 ]
机构
[1] Med Univ Innsbruck, Dept Surg & Sports Med, A-6020 Innsbruck, Austria
[2] AO Res Inst Davos, CH-7270 Davos, Switzerland
[3] Univ Munich, Anat Anstalt, D-80336 Munich, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2012年 / 43卷 / 10期
关键词
Distal radius fracture; Metaphyseal bone defect; Injectable bone substitute; Histomorphometry; TIBIAL PLATEAU FRACTURES; CALCIUM-PHOSPHATE BONE; PALMAR LOCKING-PLATE; INTERPOROUS HYDROXYAPATITE; GRAFT SUBSTITUTE; ILIAC CREST; COMPLICATIONS; FIXATION; REDUCTION; CEMENT;
D O I
10.1016/j.injury.2012.06.006
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Biodegradable calcium phosphate cements are frequently used in human patients but data regarding resorption characteristic of ChronOS (TM) Inject in metaphyseal bone defects are lacking. Six patients (range 62-81 years) with a dorsally displaced distal radius fracture were treated with volar locking plate systems and ChronOS (TM) Inject application into the metaphyseal bone defect. During implant removal (time in situ 6-15 months, average 11 months) a 2 mm diameter biopsy was obtained from the region of the previous cement injection. In all specimens' area of bone, osteoid and remaining tissue were histomorphometrically determined and presence of cement particles, bone marrow fibrosis and signs of inflammation were recorded. Vital bone tissue, osteoid formation, mast cell occurrence and marrow fibrosis were detected in most specimens. Varying but small amounts of granular material identified as remainder of the cement were detected in all specimens. Agglomerations of granular material were often surrounded by bone tissue and islets of newly formed osteoid in direct contact with the remaining cement also occurred. Bone density (i.e. area per region of interest) ranged between 6.9% and 36.2% and osteoid density between 0.5% and 7.8%. Bone osteoid ratio was higher in patients who received no osteoporosis medication and lower in patients who received osteoporosis medication (range 6.0-32.1). The present study shows that small amounts of ChronOS (TM) Inject are still detectable in human patients 15 months after implantation into a distal radius bone defect. During tissue remodelling ChronOS (TM) Inject is integrated into the newly formed trabecular bone meshwork. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1683 / 1688
页数:6
相关论文
共 35 条
[1]
In vivo behavior of three different injectable hydraulic calcium phosphate cements [J].
Apelt, D ;
Theiss, F ;
El-Warrak, AO ;
Zlinszky, K ;
Bettschart-Wolfisberger, R ;
Bohner, M ;
Matter, S ;
Auer, JA ;
von Rechenberg, B .
BIOMATERIALS, 2004, 25 (7-8) :1439-1451
[2]
Limits of palmar locking-plate osteosynthesis of unstable distal radius fractures [J].
Arora, R. ;
Lutz, M. ;
Zimmermann, R. ;
Krappinger, D. ;
Gabl, M. ;
Pechlaner, S. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2007, 39 (01) :34-41
[3]
Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures [J].
Arora, R ;
Lutz, M ;
Fritz, D ;
Zimmermann, R ;
Oberladstätter, J ;
Gabl, M .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (06) :399-404
[4]
Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[5]
Complications of iliac crest bone graft harvesting [J].
Arrington, ED ;
Smith, WJ ;
Chambers, HG ;
Bucknell, AL ;
Davino, NA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (329) :300-309
[6]
LIMITED OPEN REDUCTION OF THE LUNATE FACET IN COMMINUTED INTRA-ARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, T ;
GREEN, J ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (03) :372-377
[7]
Betz RR, 2002, ORTHOPEDICS, V25, pS561
[8]
Physical and chemical aspects of calcium phosphates used in spinal surgery [J].
Bohner, M .
EUROPEAN SPINE JOURNAL, 2001, 10 (Suppl 2) :S114-S121
[9]
BUCHOLZ RW, 1989, CLIN ORTHOP RELAT R, P53
[10]
COMPLICATIONS FOLLOWING AUTOLOGOUS BONE TRANSPLANTATION AT THE SITE OF REMOVAL [J].
DUTTING, A ;
THOMAS, W ;
LORENZ, H ;
HOLST, A .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1988, 126 (01) :44-47