Single half-wavelength ultrasonic particle filter:: Predictions of the transfer matrix multilayer resonator model and experimental filtration results

被引:55
作者
Hawkes, JJ
Coakley, WT
Gröschl, M
Benes, E
Armstrong, S
Tasker, PJ
Nowotny, H
机构
[1] Cardiff Univ, Sch Biosci, Cardiff CF10 3TL, S Glam, Wales
[2] Vienna Univ Technol, Inst Allgemeine Phys, A-1040 Vienna, Austria
[3] Cardiff Univ, Sch Engn, Ctr High Frequency Engn, Cardiff CF24 3TF, S Glam, Wales
[4] Vienna Univ Technol, Inst Theoret Phys, A-1040 Vienna, Austria
关键词
D O I
10.1121/1.1448341
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The quantitative performance of a "single half-wavelength" acoustic resonator operated at frequencies around 3 MHz as a continuous Row microparticle filter has been investigated. Standing wave acoustic radiation pressure on suspended particles (5-mum latex) drives them towards the center of the half-wavelength separation channel. Clarified suspending phase from the region closest to the filter wall is drawn away through a downstream outlet. The filtration efficiency of the device was established from continuous turbidity measurements at the filter outlet. The frequency dependence of the acoustic energy density in the aqueous particle suspension layer of the filter system was obtained by application of the transfer matrix model [H. Nowotny and E. Benes, J. Acoust. Soc. Am. 82, 513-521 (1987)]. Both the measured clearances and the calculated energy density distributions showed a maximum at the fundamental of the piezoceramic transducer and a second, significantly larger, maximum at another system's resonance not coinciding with any of the transducer or empty chamber resonances. The calculated frequency of this principal energy density maximum was in excellent agreement with the optimal clearance frequency for the four tested channel widths. The high-resolution measurements of filter performance provide, for the first time, direct verification of the matrix model predictions of the frequency dependence of acoustic energy density in the water layer. (C) 2002 Acoustical Society of America.
引用
收藏
页码:1259 / 1266
页数:8
相关论文
共 29 条
[1]  
Auld B.A., 1973, ACOUSTIC FIELDS WAVE
[2]  
Benes E., 1992, ULTR INT 91 C P, P167
[4]   A NOVEL ULTRASONIC RESONANCE FIELD DEVICE FOR THE RETENTION OF ANIMAL-CELLS [J].
DOBLHOFFDIER, O ;
GAIDA, T ;
KATINGER, H ;
BURGER, W ;
GROSCHL, M ;
BENES, E .
BIOTECHNOLOGY PROGRESS, 1994, 10 (04) :428-432
[5]  
Gaida T, 1995, ANIMAL CELL TECHNOLOGY: DEVELOPMENTS TOWARDS THE 21ST CENTURY, P699
[6]   Selective retention of viable cells in ultrasonic resonance field devices [J].
Gaida, T ;
DoblhoffDier, O ;
Strutzenberger, K ;
Katinger, H ;
Burger, W ;
Groschl, M ;
Handl, B ;
Benes, E .
BIOTECHNOLOGY PROGRESS, 1996, 12 (01) :73-76
[7]  
Gor'kov L. P., 1962, SOV PHYS DOKL, V6, P773, DOI DOI 10.1039/C004504G
[8]  
Gould R. K., 1974, Proceedings of the 1973 Symposium on Finite-Amplitude Wave Effects in Fluids, P252
[9]  
Groschl H, 1998, ACUSTICA, V84, P815
[10]  
Groschl M, 1998, ACUSTICA, V84, P632